A detailed examination of pulmonary uptake of (99m)Tc-Tin colloid in healthy mature miniature pigs.

نویسندگان

  • Kyung Mi Shim
  • Se Eun Kim
  • Changjong Moon
  • Sung-Ho Kim
  • Chun-Sik Bae
  • Ho Jae Han
  • Seong Soo Kang
چکیده

(99m)Tc-Tin colloid is a commonly used colloidal radiopharmaceutical in human medicine for evaluating liver function and morphology. (99m)Tc-Tin colloid is taken up in the liver by the phagocytic activity of Kupffer cells, the reticuloendothelial cells of the liver. Unlike what occurs in human beings, we demonstrated (99m)Tc-Tin colloid uptake within the lungs and liver in healthy, mature, miniature pigs. Our observations may be explained by the presence of pulmonary intravascular macrophages (PIMs) closely apposed to the endothelium of the pulmonary capillaries in several animal species, such as the sheep, horse, goat, cat and pig. In the current study, we compared scintigraphic images using (99m)Tc-Tin colloid in rats with those in mature, miniature pigs, and identified the presence of PIMs, reticuloentothelial cells similar to Kupffer cells, by immunohistochemistry in pigs. Pulmonary uptake of (99m)Tc-Tin colloid occurred only in pigs, and PIMs in the pulmonary capillaries stained positively for mouse monoclonal MAC387 antibodies to macrophages in lung sections, as well as Kupffer cells in liver sections. Therefore, we conclude that the uptake of intravenously injected (99m)Tc-Tin colloid within both Kupffer cells and PIMs results in scintigraphic imaging of the lung and liver in miniature pigs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of Tc-sn-colloid kit for liver-spleen imaging [Persian]

When Tc-99m-sulfur colloid was introduced as an ideal liver-spleen agent in nuclear medicine, many other types of colloids followed by different manufacturers. They hoped to find a suitable colloidal agent, contrary to sulfur colloid, which is easy to use, and less sensitive to the low contamination of aluminum ions. One of this type of colloid agents, is Tc-99-tin-colloid which is prepar...

متن کامل

Massive hepatomegaly in 99mTc-octreotide scintigraphy: The value of 99mTc-sulfur colloid scan

99mTc-octreotide scintigraphy, performed during the following up a 58-year old man with neuroendocrine tumor demonstrated massive hepatomegaly demonstrating multiple areas of increased and decreased uptake. Due to severe hepatomegaly concurrence of any other abdominal soft tissue lesions could not be excluded. A 99mTc-sulfur colloid scan was done and thoroughly compared wi...

متن کامل

Size Control of 99mTc-tin Colloid Using PVP and Buffer Solution for Sentinel Lymph Node Detection

Colloidal particle size is an important characteristic that allows mapping sentinel nodes in lymphoscintigraphy. This investigation aimed to introduce different ways of making a (99m)Tc-tin colloid with a size of tens of nanometers. All agents, tin fluoride, sodium fluoride, poloxamer-188, and polyvinylpyrrolidone (PVP), were mixed and labeled with (99m)Tc. Either phosphate or sodium bicarbonat...

متن کامل

In Vitro Evaluation of Tc-99m Radiopharmaceuticals for Gastric Emptying Studies

OBJECTIVE Gastrointestinal motility and functional motility disorders causing either delayed or accelerated gastric emptying (GE) may result in similar symptoms including nausea, vomiting, early satiety, fullness, bloating, and abdominal discomfort or pain. Hence, it is important to evaluate patients for both rapid and delayed GE in the same test. The gold standard technique to measure GE is sc...

متن کامل

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

  Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • In vivo

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2009