A new low threshold platinized epicardial pacing electrode: comparative evaluation in immature canines.
نویسندگان
چکیده
A prospective comparison of pacing and sensing capabilities between the conventional Medtronic Model 4951 platinum-iridium epicardial pacing electrode and a new modified "platinized" version of the same electrode was performed in immature canines to determine if the new electrode design improves pacing in the immature myocardium. The conventional electrode was modified by electroplating platinum black particles onto the surface to increase the effective or true microscopic surface area, yet essentially maintain the same overall geometric electrode size. Both epicardial electrodes were inserted into the right ventricular myocardium with the lead pad sutured to the epicardium, and externalized to the scruff in five puppies (age 3 months). An additional left ventricular lead was implanted to permit chronic pacing following epicardially-induced atrioventricular block. Acute and chronic sensing and pacing capabilities of each externalized electrode were performed at implant and weekly up to 4 months. Histologic examination of each electrode implant site was performed at the end of the study period. At implant, both electrodes exhibited comparable values for sensed R waves, lead impedances, and pacing thresholds. During the study, the platinized electrode exhibited lower pacing thresholds. Analysis of all postimplant data demonstrated this threshold difference to be significantly lower (P less than .01) for the platinized version. Lead impedance and sensing capabilities remained comparable between the two designs. Histologic study demonstrated less fibrotic infiltration at the platinized electrode site. This preliminary evaluation indicates that for the duration of the postimplant study period, the platinized epicardial electrode design was associated with significantly lower thresholds and less fibrosis as a function of time compared to the conventional smooth electrode surface design. The new platinized electrode limits exit block in the developing immature myocardium and permits safe pacing at lower pulse widths and voltages to increase battery life.
منابع مشابه
Long-term performance of transvenous, steroid-eluting, high impedance, passive-fixation ventricular pacing leads.
The long-term performance of two high impedance, steroid-eluting, passive-fixation ventricular leads, porous platinum iridium electrode CPI Selute Picotip 4035 (131 patients), and platinized platinum electrode Medtronic Capsure Z 5034 (57 patients), was compared with one conventional 8.0-mm2 porous platinum iridium electrode CPI Selute 4285 (38 patients). The mean follow-up period was 28 +/- 14...
متن کاملPercutaneous Epicardial Pacing using a Novel Insulated Multi-electrode Lead.
INTRODUCTION Epicardial cardiac resynchronization therapy (CRT) permits unrestricted electrode positioning. However, this requires surgical placement of device leads and the risk of unwanted phrenic nerve stimulation. We hypothesized that shielded electrodes can capture myocardium without extracardiac stimulation. METHODS In 6 dog and 5 swine experiments, we used a percutaneous approach to ac...
متن کاملIn vivo effects of mid-myocardial pacing on transmural dispersion of repolarization and conduction in canines
OBJECTIVE In our previous in vitro study mid-myocardial relative to epicardial pacing decreased transmural dispersion of depolarization (TDR) and prevented ventricular arrhythmia. We therefore hypothesized that in vivo mid-myocardial pacing in canines has a similar effect. METHODS AND RESULTS Using custom-made electrodes, monophasic action potentials were simultaneously recorded in vivo from ...
متن کاملDo daily threshold trend fluctuations of epicardial leads correlate with pacing and sensing characteristics in paediatric patients?
AIMS To evaluate whether the magnitude of daily ventricular pacing threshold fluctuations (Deltafluctuation) in trend graphs of stored diagrams correlate with ventricular threshold and sensing changes over time. METHODS AND RESULTS A total of 56 children received AutoCapture devices (St. Jude Medical, Sylmar, CA, USA) connected to steroid-eluting epicardial leads. Maximum lead age at study cl...
متن کاملValidation of electromechanical wave imaging in a canine model during pacing and sinus rhythm.
BACKGROUND Accurate determination of regional areas of arrhythmic triggers is of key interest to diagnose arrhythmias and optimize their treatment. Electromechanical wave imaging (EWI) is an ultrasound technique that can image the transient deformation in the myocardium after electrical activation and therefore has the potential to detect and characterize location of triggers of arrhythmias. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 11 8 شماره
صفحات -
تاریخ انتشار 1988