Endovascular treatment of carotid artery stenosis: retrospective study of 79 patients treated with stenting and angioplasty with and without cerebral protection devices.

نویسندگان

  • Eduardo Noda Kihara
  • Mario Sergio Duarte Andrioli
  • Eliova Zukerman
  • Mario Fernando Prieto Peres
  • Pedro Paulo Porto Júnior
  • Paulo Hélio Monzillo
  • Ivan Hideyo Okamoto
  • Ayrton Roberto Massaro
  • José Carlos Zirretta
چکیده

We evaluate the results of stenting and angioplasty on carotid bifurcation stenotic lesions using protection systems, emphasizing the indications and technical aspects. Seventy-nine patients, mean age 64.5 years were treated from February,1998 to March, 2003. All patients were included in NASCET study criteria. Forty three patients were treated without the protection systems and thirty six were treated with carotid protection filtering system (Angioguard, EPI). Technical success and 6-months carotid Doppler ultrasound follow-up showing stent patency were achieved in all patients. One major stroke and one death due to intracranial reperfusion bleeding occurred in patients treated without cerebral protection devices. Only one patient presenting hyper perfusion syndrome improving after 7 days, was found in the group treated with the cerebral protection filter mechanism, no other neurologic symptom or death occurred in this group. Stenting and angioplasty with protection systems for thromboembolic debris is a safe endovascular method to treat stenotic lesions in the carotid bifurcation with low morbidity and mortality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

Intracranial internal carotid artery stenosis with vulnerable plaques successfully treated by stenting under cerebral protection.

Percutaneous transluminal angioplasty with stenting (PTA/stenting) for intracranial atherosclerotic stenoses is usually performed without any protection devices. We report a unique case of atherothrombotic stenosis with the vulnerable plaque in the cavernous portion of the internal carotid artery (ICA), which was successfully treated by PTA/stenting under cerebral protection with the flow rever...

متن کامل

Carotid artery stenting with filter protection in high-risk patients showing severe electroencephalographic alterations during carotid endarterectomy.

PURPOSE To describe the results and efficacy of stent treatment in patients with carotid stenosis who had aborted carotid endarterectomy procedures due to the appearance of severe electroencephalographic (EEG) alterations. METHODS A retrospective study was conducted of 18 patients (11 men; mean age 72 years, range 62-84) with symptomatic high-grade carotid artery stenoses (> or = 70%) who exp...

متن کامل

Restenosis after carotid angioplasty, stenting, or endarterectomy in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

BACKGROUND AND PURPOSE Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS) patients with carotid stenosis were randomized between endovascular treatment and endarterectomy. The rates of residual severe stenosis and restenosis and their contribution to recurrent symptoms was unclear. METHODS Endovascular patients were treated by balloon angioplasty alone (88%) or stenting (22...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos de neuro-psiquiatria

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 2004