Symmetric image registration with directly calculated inverse deformation field

نویسندگان

  • Bartlomiej W. Papież
  • Bogdan J. Matuszewski
چکیده

This paper presents a novel technique for a symmetric deformable image registration based on a new method for fast and accurate direct inversion of a large motion model deformation field. The proposed image registration algorithm maintain a one-to-one mapping between registered images by symmetrically warping them to each other, and by ensuring the inverse consistency criterion at each iteration. This makes the final estimation of forward and backward deformation fields anatomically plausible. The quantitative validation of the method has been performed on magnetic resonance data obtained for a pelvis area demonstrating applicability of the method to adaptive prostate radiotherapy. The experiments demonstrate the improved robustness in terms of inverse consistency error when compared to previously proposed methods for symmetric image registration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct inverse deformation field approach to pelvic-area symmetric image registration

This paper presents a novel technique for a consistent symmetric deformable image registration based on an accurate method for a direct inversion of a large motion model deformation field. The proposed image registration algorithm maintains one-to-one mapping between registered images by symmetrically warping them to another image. This makes the final estimation of forward and backward deforma...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

Consistent and Elastic Registration of Histological Sections Using Vector-Spline Regularization

Here we present a new image registration algorithm for the alignment of histological sections that combines the ideas of B-spline based elastic registration and consistent image registration, to allow simultaneous registration of images in two directions (direct and inverse). In principle, deformations based on B-splines are not invertible. The consistency term overcomes this limitation and all...

متن کامل

Regularization in deformable registration of biomedical images based on divergence and curl operators.

BACKGROUND Similarity measures in medical images do not uniquely determine the correspondence between two voxels in deformable image registration. Uncertainties in the final computed deformation exist, questioning the actual physiological consistency of the deformation between the two images. OBJECTIVES We developed a deformable image registration method that regularizes the deformation field...

متن کامل

Inverse Consistent Mapping in 3D Deformable Image Registration: Its Construction and Statistical Properties

This paper presents a new approach to inverse consistent image registration. A uni-directional algorithm is developed using symmetric cost functionals and regularizers. Instead of enforcing inverse consistency using an additional penalty that penalizes inconsistency error, the new algorithm directly models the backward mapping by inverting the forward mapping. The resulting minimization problem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -