Fracture care using percutaneously applied titanium mesh cages (OsseoFix®) for unstable osteoporotic thoracolumbar burst fractures is able to reduce cement-associated complications—results after 12 months

نویسندگان

  • Stephan Albrecht Ender
  • Anica Eschler
  • Michaela Ender
  • Harry Rudolf Merk
  • Ralph Kayser
چکیده

BACKGROUND Despite the known demographic shift with expected doubled rate of vertebral body fractures by the year 2050, a standardized treatment concept for traumatic and osteoporotic incomplete burst fracture of the truncal spine does not exist. This study aims to determine whether minimally invasive fracture care for incomplete osteoporotic thoracolumbar burst fractures using intravertebral expandable titanium mesh cages is a suitable procedure and may provide improved safety in terms of cement-associated complications in comparison to kyphoplasty procedure. METHODS In 2011/2012, 15 patients (10 women, 5 men; mean age 77) with 15 incomplete osteoporotic thoracolumbar burst fractures (T10 to L4) were stabilized using intravertebral expandable titanium mesh cages (OsseoFix®) as part of a prospective study. X-ray, MRI and bone density measurements (DXA) were performed preinterventionally. The clinical and radiological results were evaluated preoperatively, postoperatively and after 12 months according to the visual analogue scale (VAS), the Oswestry Disability Index (ODI), X-ray (Beck Index, Cobb angle) and CT analyses. Wilcoxon rank sum test, sign test and Fischer's exact test were used for statistical evaluation. RESULTS A significant reduction in pain intensity (VAS) from preoperative 8.0 to 1.6 after 12 months and significant improvement in activity level (ODI) from preoperative 79.0 to 30.5 % after 12 months were revealed. Radiologically, the mean kyphotic angle according to Cobb showed significant improvements from preoperative 9.1° to 8.0° after 12 months. A vertebral body subsidence was revealed in only one case (6.7 %). No changes in the position of the posterior wall were revealed. No cement leakage or perioperative complications were seen. CONCLUSION As a safe and effective procedure, the use of intravertebral expandable titanium mesh cages presents a valuable alternative to usual intravertebral stabilization procedures for incomplete osteoporotic burst fractures and bears the potential to reduce cement-associated complications. TRIAL REGISTRATION German Clinical Trials Register (DKRS) DRKS00008833 .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Bony Healing of Unstable Thoracolumbar Burst Fractures in the Elderly Using Percutaneously Applied Titanium Mesh Cages and a Transpedicular Fixation System with Expandable Screws

INTRODUCTION There is a high incidence of vertebral burst fractures following low velocity trauma in the elderly. Treatment of unstable vertebral burst fractures using the same principles like in stable vertebral burst fractures may show less favourable results in terms of fracture reduction, maintenance of reduction and cement leakage. In order to address these shortcomings this study introduc...

متن کامل

Osseofix® System for Percutaneous Stabilization of Osteoporotic and Tumorous Vertebral Compression Fractures – Clinical and Radiological Results After 12 Months Minimalinvasive perkutane Stabilisierung osteoporotischer und tumoröser Wirbelkörperfrakturen mit dem Osseofix®-System – klinische und radiologische Ergebnisse nach 12 Monaten

Purpose: Determining whether implantation of an expandable titanium mesh cage (Osseofix® system) is a successful and safeminimally invasive therapy for osteoporotic and tumorous vertebral compression fractures (VCFs). Materials and Methods: 32 patients (25 women, 7 men, mean age 71) with 46 osteoporotic or tumorous VCFs (T6 to L4) from June 2010 to January 2012 were included. All of them were s...

متن کامل

Percutaneous Stabilization System Osseofix® for Treatment of Osteoporotic Vertebral Compression Fractures - Clinical and Radiological Results after 12 Months

STUDY DESIGN A prospective consecutive cohort study (follow-up study). OBJECTIVE Our study investigated whether implantation of an expandable titanium mesh cage (Osseofix®) is a successful and safe minimally invasive therapy for osteoporotic vertebral compression fractures (VCF). Our experiences, clinical and radiological findings after 12 months follow-up are presented. Kypho- and vertebropl...

متن کامل

Cementless Fixation of Osteoporotic VCFs Using Titanium Mesh Implants (OsseoFix): Preliminary Results

INTRODUCTION Vertebral compression fractures (VCFs) affect 20% of people over the age of 70 with increasing incidence. Kypho-/vertebroplasty as standard operative procedures are associated with limitations like cement leakage, limited reduction capabilities, and risk for adjacent fractures. To address these shortcomings, we introduce a new minimal invasive cementless VCF fixation technique. M...

متن کامل

Cementless Titanium Mesh Fixation of Osteoporotic Burst Fractures of the Lumbar Spine Leads to Bony Healing: Results of an Experimental Sheep Model

INTRODUCTION Current treatment strategies for osteoporotic vertebral compression fractures (VCFs) focus on cement-associated solutions. Complications associated with cement application are leakage, embolism, adjacent fractures, and compromise in bony healing. This study comprises a validated VCF model in osteoporotic sheep in order to (1) evaluate a new cementless fracture fixation technique us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015