Sonographic assessment of the inferior vena cava/aorta index measured with the transducer placed in the anterior median line and right anterior axillary line – a comparison

نویسندگان

  • Monika Luboch
  • Magdalena Łoś
  • Łukasz Szmygel
  • Wojciech Kosiak
چکیده

UNLABELLED The aim of the study was to compare the values of the sonographic inferior vena cava/ aorta index obtained with the transducer placed in the median line and right anterior axillary line. MATERIAL AND METHODS The study enrolled 45 volunteers, including 33 women, aged 22.5 ± 1.26 with a negative history of circulatory and renal diseases. The study consisted in a sonographic assessment and measurement of the inferior vena cava and aorta by placing the transducer in the anterior median line and right anterior axillary line. The value of the inferior vena cava/aorta index was obtained by calculating the ratio of the diameters of the inferior vena cava and aorta. The diameter measurements were taken by placing the ultrasound transducer in the anterior median line and right anterior axillary line. Two examiners performed the measurement three times and used convex probes of 3.5-5 MHz. Additionally, the subjects' weight, height and arterial blood pressure were taken. RESULTS Following a statistical analysis with the use of STATISTICA software, the following values of the inferior vena cava/aorta index were obtained: in the anterior median line - 1.43 ± 0.21, and in the right anterior axillary line - 1.285 ± 0.19. There was no statistically significant difference between the measurements obtained by the two examiners (p = 0.17). A strong correlation was noted between the inferior vena cava/ aorta indices calculated in both sites of transducer placement, which was irrespective of the examiners (the correlation coefficient: r = 0.61 and r = 0.71). The study indicate that the inferior vena cava/aorta index measured in the right anterior axillary line is a simple and reproducible method for determining the body fluid status; the examinations conducted in both sites may be used interchangeably. Further studies are needed to determine reference values for the inferior vena cava/aorta index measured in the right anterior axillary line.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults

The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta dia...

متن کامل

Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

INTRODUCTION The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal ...

متن کامل

Multifactorial Neonatal Thrombosis in Inferior Vena Cava Dislodged to the Right Atrium: A Case Report

Background: Neonatal thrombotic diseases can cause mortality or serious morbidity and disability.Case report: In this report, we present a case of neonatal inferior vena cava thromboembolism with several underlyingfactors. Hereditary thrombophilia and genetic mutation in plasminogen activator inhibitor-1 and MTHFR A1298C genesin conjunction with cleft palate resulted in poor l...

متن کامل

Evaluation of infradiaphragmatic total anomalous pulmonary venous connection with two-dimensional echocardiography.

In three newborn infants with infradiaphragmatic total anomalous pulmonary venous connection, the common pulmonary vein was visualized with two-dimensional echocardiography and validated with saline contrast injections. The transducer was placed in the subcostal region in a sagittal body plane so as to image the descending aorta and the vertebral column. The common pulmonary vein, which connect...

متن کامل

Ultrasonographic Assessment of Caudal Vena Cava to Aorta Ratio as a Novel Endpoint in Hemorrhagic Shock Resuscitation in Dogs

Objective- The aim of this study was to assess ultrasonography-derived caudal vena cava to aorta ratio (CVC/Ao) as a novel endpoint in the resuscitation of experimental hemorrhagic shock in dogs. Design- Experimental study. Animals- Ten adult mongrel healthy dogs. Procedures- After induction of anesthesia (con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014