Fourier transformed atomic force microscopy: tapping mode atomic force microscopy beyond the Hookian approximation

نویسندگان

  • Robert W. Stark
  • Wolfgang M. Heckl
چکیده

The periodic impact force induced by the tip–sample contact in tapping mode atomic force microscopy (TM-AFM) gives rise to anharmonic oscillations of the sensing cantilever. These anharmonic signals can be understood with a model which goes beyond the common Hookian approximation: the cantilever is described as a multiple degree of freedom system. A theoretical analysis of the anharmonic signals in the light of the extended model shows that these signals contain information on the elastic properties of the specimen surface. In Fourier transformed operation mode of TM-AFM the anharmonic oscillations are analyzed in the frequency domain. This allows for the reconstruction of characteristics of the tip–sample force, like contact time and maximum contact force. © 2000 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters

In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...

متن کامل

Tapping mode atomic force microscopy in liquid

We show that standard silicon nitride cantilevers can be used for tapping mode atomic force microscopy (AFM) in air, provided that the energy of the oscillating cantilever is sufficiently high to overcome the adhesion of the water layer. The same cantilevers are successfully used for tapping mode AFhif in liquid. Acoustic modes in the liquid excite the canti1eve.r. On soft samples, e.g., biolog...

متن کامل

Harnessing bifurcations in tapping-mode atomic force microscopy to calibrate time-varying tip-sample force measurements.

Torsional harmonic cantilevers allow measurement of time-varying tip-sample forces in tapping-mode atomic force microscopy. Accuracy of these force measurements is important for quantitative nanomechanical measurements. Here we demonstrate a method to convert the torsional deflection signals into a calibrated force wave form with the use of nonlinear dynamical response of the tapping cantilever...

متن کامل

Phase imaging and stiffness in tapping-mode atomic force microscopy

The dependence of phase angles in tapping-mode atomic force microscopy on the magnitude of tip-sample repulsive interactions was investigated, and phase images of several hard and soft samples were recorded as a function of the free amplitude Ao and the set-point tapping amplitude Asp. The phase angle of probe oscillation increases with decreasing the set-point amplitude ratio Asp/Ao. Phase ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000