Legionella pneumophila in residential water supplies: environmental surveillance with clinical assessment for Legionnaires' disease.

نویسندگان

  • J E Stout
  • V L Yu
  • Y C Yee
  • S Vaccarello
  • W Diven
  • T C Lee
چکیده

Although cases of community-acquired Legionnaires' disease have been epidemiologically linked to residential water supplies, the risk of acquiring Legionnaires' disease from exposure to Legionella pneumophila in residential water systems is uncertain. The residential water supplies of 218 members of the American Legion in six different geographical areas in Pittsburgh were cultured for L. pneumophila. Residents of the homes provided a recent medical history and a blood sample for detection of antibodies to legionella. A urine sample for legionella urinary antigen testing was also requested from individuals residing in legionella-positive homes and individuals with a positive antibody test. Six percent (14/218) of the homes yielded L. pneumophila (range within six areas 0-22%). Lower hot water tank temperature was significantly associated with legionella positivity (P less than 0.01). Analysis of water samples for mineral content showed no association between legionella positivity and concentrations of calcium and magnesium. Water samples from the area where 22% of the homes surveyed were positive for legionella had a higher iron content than water samples from the other areas tested. None of the individuals residing in legionella-positive homes showed elevated antibody titres to legionella or the presence of legionella antigen in urine. For the immunocompetent hosts, the risk of contracting Legionnaires' disease from exposure to contaminated household water supplies in the Pittsburgh area appears to be low.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Persistence of Legionella in hospital water supplies and nosocomial Legionnaires' disease.

The molecular epidemiology of clinical and environmental Legionella species isolates was studied in seven hospitals from 1989 to 2006. The number of environmental pulsed field gel electrophoresis (PFGE) patterns ranged from one to nine according to the hospital. Genomic PFGE pattern persistence was observed in 71% of the hospitals, even after 17 years in some hospitals, and the relationship bet...

متن کامل

Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan

Coinciding with major changes to its municipal water system, Flint, MI, endured Legionnaires' disease outbreaks in 2014 and 2015. By sampling premise plumbing in Flint in the fall of 2016, we found that 12% of homes harbored legionellae, a frequency similar to that in residences in neighboring areas. To evaluate the genetic diversity of Legionella pneumophila in Southeast Michigan, we determine...

متن کامل

Pulsed field electrophoresis of genomic restriction fragments for the detection of nosocomial Legionella pneumophila in hospital water supplies.

Ten Legionella pneumophila strains isolated from different sources were analyzed according to their restriction fragment patterns obtained by cleavage of genomic DNA with NotI and SfiI and separation by pulsed field electrophoresis. Three L. pneumophila isolates from a nosocomial outbreak in Lübeck (Germany) and three other L. pneumophila strains independently isolated from a water tap located ...

متن کامل

Potable water as a cause of sporadic cases of community-acquired legionnaires' disease.

BACKGROUND The environmental sources of sporadic, community-acquired legionnaires' disease are largely unknown, and culturing of water sources after identification of a case is currently not recommended. We conducted a prospective study of sporadic cases of community-acquired legionnaires' disease to determine whether the environmental reservoirs could be identified. METHODS We cultured sampl...

متن کامل

Nosocomial Legionnaires' disease caused by Legionella pneumophila serogroup 5: laboratory and epidemiologic implications.

Environmental monitoring and clinical surveillance for Legionella species were done for 12 months as recommended by the Allegheny County Health Department (Pittsburgh). The water system of a hospital was found to be colonized with Legionella pneumophila serogroup 5. Three patients with nosocomial L. pneumophila serogroup 5 disease were subsequently diagnosed after laboratory tests for legionell...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Epidemiology and infection

دوره 109 1  شماره 

صفحات  -

تاریخ انتشار 1992