Comparison of frequency response and aided speech-recognition performance for hearing aids selected by three different prescriptive methods.

نویسندگان

  • L Humes
  • T Hackett
چکیده

The gain and the speech-recognition performance obtained for behind-the-ear (BTE) hearing aids selected by different prescriptive methods was compared. The three prescriptive methods examined were the NAL-revised method, the Memphis State or COX method, and the POGO-II procedure. Twelve subjects had hearing aids and earmolds selected to match the prescription made by each method. Once selected, the instruments were fine tuned to match the obtained gain to that prescribed and then speech recognition was assessed. Subjects listened to the CUNY Nonsense Syllable Test (NST) in quiet and in noise. Results indicated that, although the prescribed frequency responses differed significantly among methods, there were no differences among the three prescriptive methods in obtained frequency responses or aided speech-recognition performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating performance with high-frequency emphasis amplification.

Hearing aid fitting for individuals with high-frequency impairment has been difficult because of the limited gain available at those frequencies. Special high-frequency emphasis hearing aids have been developed in an attempt to alleviate this problem. The insertion-gain responses and changes in speech-recognition performance (in quiet and in noise, aided and unaided) were measured for a commerc...

متن کامل

Performance of custom-fit versus fixed-format hearing aids for precipitously sloping high-frequency hearing loss.

This study compared the real-ear response provided by custom-fit hearing aids to the closest matching fixed-format disposable hearing aids in patients with precipitous high-frequency hearing loss. Laboratory and field measures of aided performance were obtained to compare patient performance with the custom-fit and fixed-format hearing aids. In addition, coupler versus real-ear response differe...

متن کامل

A comparison of the aided performance and benefit provided by a linear and a two-channel wide dynamic range compression hearing aid.

The aided performance and benefit achieved with linear and two-channel wide dynamic range compression (WDRC) in-the-canal (ITC) hearing aids were established in 55 individuals. Study participants had been wearing either linear or adaptive-frequency-response (Bass Increase at Low Levels, BILL) ITC hearing aids for approximately one year before participation in this study. Outcome measures includ...

متن کامل

مقایسه وضوح گفتار کودکان کاشت حلزون شده، دارای سمعک و کودکان با شنوایی هنجار

Objective: The purpose of the present research was to compare speech intelligibility in children with cochlear implant, with hearing aids and normal hearing in Tehran province.  Materials & Methods: Sixty children underwent this analytic and comparative research. They were divided into three groups and each group contains 20 children. First and second group were selected, ordinarily, from ch...

متن کامل

Comparison of performance across three directional hearing aids.

This study compared the speech recognition performance of 12 hearing-impaired listeners fit with three commercially available behind-the-ear hearing aids in both directional and omnidirectional modes. One digitally programmable analog and two "true digital" hearing aids were selected as test instruments. Testing was completed in both "living room" and anechoic room environments. Speech recognit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 1990