Multi-graphical analysis of dynamic PET
نویسندگان
چکیده
In quantitative dynamic PET studies, graphical analysis methods including the Gjedde-Patlak plot, the Logan plot, and the relative equilibrium-based graphical plot (RE plot) (Zhou Y., Ye W., Brasić J.R., Crabb A.H., Hilton J., Wong D.F. 2009b. A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies. Neuroimage 44(3):661-670) are based on the theory of a compartmental model with assumptions on tissue tracer kinetics. If those assumptions are violated, then the resulting estimates may be biased. In this study, a multi-graphical analysis method was developed to characterize the non-relative equilibrium effects on the estimates of total distribution volume (DV(T)) from the RE plot. A novel bi-graphical analysis method using the RE plot with the Gjedde-Patlak plot (RE-GP plots) was proposed to estimate DV(T) for the quantification of reversible tracer kinetics that may not be at relative equilibrium states during PET study period. The RE-GP plots and the Logan plot were evaluated by 19 [(11)C]WIN35,428 and 10 [(11)C]MDL100,907 normal human dynamic PET studies with brain tissue tracer kinetics measured at both region of interest (ROI) and pixel levels. A 2-tissue compartment model (2TCM) was used to fit ROI time activity curves (TACs). By applying multi-graphical plots to the 2TCM fitted ROI TACs which were considered as the noise-free tracer kinetics, the estimates of DV(T) from the RE-GP plots, the Logan plot, and the 2TCM fitting were equal to each other. For the measured ROI TACs, there was no significant difference between the estimates of the DV(T) from the RE-GP plots and those from 2TCM fitting (p=0.77), but the estimates of the DV(T) from the Logan plot were significantly (p<0.001) lower, 2.3% on average, than those from 2TCM fitting. There was a highly linear correlation between the ROI DV(T) from the parametric images (Y) and those from the ROI kinetics (X) by using the RE-GP plots (Y=1.01X+0.23, R(2)=0.99). For the Logan plot, the ROI estimates from the parametric images were 13% to 83% lower than those from ROI kinetics. The computational time for generating parametric images was reduced by 69% on average by the RE-GP plots in contrast to the Logan plot. In conclusion, the bi-graphical analysis method using the RE-GP plots was a reliable, robust and computationally efficient kinetic modeling approach to improve the quantification of dynamic PET.
منابع مشابه
Whole-body PET parametric imaging employing direct 4D nested reconstruction and a generalized non-linear Patlak model
Graphical analysis is employed in the research setting to provide quantitative estimation of PET tracer kinetics from dynamic images at a single bed. Recently, we proposed a multi-bed dynamic acquisition framework enabling clinically feasible whole-body parametric PET imaging by employing post-reconstruction parameter estimation. In addition, by incorporating linear Patlak modeling within the s...
متن کاملOptimising Graphical Techniques Applied to Irreversible Tracers
Graphical analysis techniques are often applied to positron emission tomography (PET) images to estimate physiological parameters. Patlak analysis is primarily used to obtain the rate constant (Ki) that indicates the transfer of a tracer from plasma to the irreversible compartment and ultimately describes how the tracer binds to the targeted tissue. One of the most common issues associated with...
متن کاملGraphical Analysis of Multi-Environment Trials for Barley Yield Using AMMI and GGE-Biplot Under Rain-Fed Conditions
The AMMI and SREG GGE are among the models that effectively capture the additive and multiplicative components of genotype × environment interaction (GEI) and provide meaningful interpretation of multi-environment trials’ data set in the breeding programs. The objective of this study was to assess the effect of GEI on grain yield of barely advanced lines and exploit the positive GEI effect us...
متن کاملWhole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction.
Whole-body (WB) dynamic PET has recently demonstrated its potential in translating the quantitative benefits of parametric imaging to the clinic. Post-reconstruction standard Patlak (sPatlak) WB graphical analysis utilizes multi-bed multi-pass PET acquisition to produce quantitative WB images of the tracer influx rate K i as a complimentary metric to the semi-quantitative standardized uptake va...
متن کاملDynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.
In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15-20 cm) of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 49 4 شماره
صفحات -
تاریخ انتشار 2010