Reliability of a 2-bout exercise test on a wattbike cycle ergometer.

نویسندگان

  • Matthew W Driller
  • Christos K Argus
  • Jason C Bartram
  • Jacinta Boniventura
  • David T Martin
  • Nicholas P West
  • Shona L Halson
چکیده

PURPOSE To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). METHODS Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg-1 · min-1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured to determine intraday (test 1 [T1] to test 2 [T2]) and interday reliability (weeks 1-6) over the repeated trials. RESULTS The mean intraday reliabilities of the 2 × 4MMP test, as expressed by the typical error of measurement (TEM, W) and coefficient of variation (CV, %) over the 6 wk, were 10.0 W (95% confidence limits [CL] 8.2-11.8), and 2.6% (95%CL 2.1-3.1), respectively. The mean interday reliability TEM and CV for T1 over the 6 wk were 10.4 W (95%CL 8.7-13.3) and 2.7% (95%CL 2.3-3.5), respectively, and 11.7 W (95%CL 9.8-15.1) and 3.0% (95%CL 2.5-3.9) for T2. CONCLUSION The testing protocol performed on a Wattbike cycle ergometer in the current study is reproducible in highly trained cyclists. The high intraday and interday reliability make it a reliable method for monitoring cycling performance and for investigating factors that affect performance in cycling events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The reliability of a 30-s sprint test on the Wattbike cycle ergometer.

PURPOSE To determine the reliability of a 30-s sprint cycle test on the Wattbike cycle ergometer. METHODS Over 3 consecutive weeks, 11 highly trained cyclists (mean ± SD; age 31 ± 6 y, mass 74.6 ± 10.6 kg, height 180.5 ± 8.1cm) completed four 30-s maximal sprints on a Wattbike ergometer after a standardized warm-up. The sprint test implemented a "rolling start" that consisted of a 60-s preloa...

متن کامل

Validity and reliability of the Wattbike cycle ergometer.

The purpose of this study was to assess the validity and reliability of the Wattbike cycle ergometer against the SRM Powermeter using a dynamic calibration rig (CALRIG) and trained and untrained human participants. Using the CALRIG power outputs of 50-1 250  W were assessed at cadences of 70 and 90  rev x min(-1). Validity and reliability data were also obtained from 3 repeated trials in both t...

متن کامل

Reproducibility of a Laboratory Based 1-km Wattbike Cycling Time Trial in Competitive Cyclists

The purpose of this study was to evaluate the reliability of a 1-km cycling time trial using a Wattbike cycling ergometer in competitive cyclists. Ten competitive male cyclists (mean ± SD; 63.9 ± 5.1 mL•kg -1 •min -1 ) performed a VO2max test and a familiarization of the 1-km time trial (TT) on the same day, and 3 separate 1-km TT (TT1, TT2 and TT3) separated by >24 hours. Mean performance time...

متن کامل

The validity and reliability of a sample of 10 Wattbike cycle ergometers.

The purpose of the study was to assess the validity and inter-bike reliability of 10 Wattbike cycle ergometers, and to assess the test-retest reliability of one Wattbike. Power outputs from 100 to 1000 W were applied using a motorised calibration rig (LODE) at cadences of 70, 90, 110 and 130 rev · min-1, which created nineteen different intensities for comparison. Significant relationships (P <...

متن کامل

Submaximal cardiopulmonary thresholds on a robotics-assisted tilt table, a cycle and a treadmill: a comparative analysis

BACKGROUND The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sports physiology and performance

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2014