Mastoid cavity dimensions and shape: method of measurement and virtual fitting of implantable devices.
نویسندگان
چکیده
Temporal bone implants can be used to electrically stimulate the auditory nerve, to amplify sound, to deliver drugs to the inner ear and potentially for other future applications. The implants require storage space and access to the middle or inner ears. The most acceptable space is the cavity created by a canal wall up mastoidectomy. Detailed knowledge of the available space for implantation and pathways to access the middle and inner ears is necessary for the design of implants and successful implantation. Based on temporal bone CT scans a method for three-dimensional reconstruction of a virtual canal wall up mastoidectomy space is described. Using Amira software the area to be removed during such surgery is marked on axial CT slices, and a three-dimensional model of that space is created. The average volume of 31 reconstructed models is 12.6 cm(3) with standard deviation of 3.69 cm(3), ranging from 7.97 to 23.25 cm(3). Critical distances were measured directly from the model and their averages were calculated: height 3.69 cm, depth 2.43 cm, length above the external auditory canal (EAC) 4.45 cm and length posterior to EAC 3.16 cm. These linear measurements did not correlate well with volume measurements. The shape of the models was variable to a significant extent making the prediction of successful implantation for a given design based on linear and volumetric measurement unreliable. Hence, to assure successful implantation, preoperative assessment should include a virtual fitting of an implant into the intended storage space. The above-mentioned three-dimensional models were exported from Amira to a Solidworks application where virtual fitting was performed. Our results are compared to other temporal bone implant virtual fitting studies. Virtual fitting has been suggested for other human applications.
منابع مشابه
Computer-aided surgical planning for implantation of hearing aids based on CT data in a VR environment.
A study was undertaken to assess the feasibility of a preoperative fitting test for an implantable hearing aid in a virtual reality (VR) environment. High-resolution spiral computed tomography (CT) of the mastoid bone was performed, and the results of a mastoidectomy were simulated with manual segmentation on a standard medical workstation. CT was also performed on a temporal bone specimen obta...
متن کاملMastoid Cavity Obliteration with Combined Palva Flap and Bone pâté
Introduction: This study was designed to evaluate the usefulness of mastoid cavity obliteration with combined bone pâté and Palva flap in the prevention of problematic mastoid cavities after canal wall down mastoidectomy. Materials and Methods: In a prospective longitudinal study with a mean follow-up of 28 months conducted between 2008–2012, a series of 56 ears in 48 patients with chronic ot...
متن کاملEndoscopic Middle Ear and Mastoid Surgery for Cholesteatoma
Introduction: To reduce incidence of residual cholesteatoma following ear surgery; and to reduce the need for second look “open” mastoidectomy using endoscopic mastoidotomy. Ten-year retrospective chart review of 249 primary cholesteatoma cases (1994-2004) with a minimum follow-up of two years. The first objective was to evaluate the effectiveness of otoendoscopy in reducing the incidence of “...
متن کاملMODIFIED RADICAL MASTOIDECTOMY: TECHNIQUES TO DECREASE FAILURE
The aims of surgical treatment for cholesteatoma include complete removal of disease and formation of a dry, self cleaning ear in addition to hearing reconstruction. This presentation concentrates on techniques of open mastoid surgery or modified radical mastoidectomy to achieve a well-constructed cavity. This study analyzes both primary and revision mastoid surgery referred to the author. ...
متن کاملدستگاههای کاشتپذیر برای کودکان ناشنوا
The idea of providing hearing to profoundly deaf patients by artificially stimulating the sensory system has progressed from a futuristic possibility to reality. Generally, an implantable hearing device is designed to capture sound and present it to the auditory system, where at least part of the device is surgically implanted in the child receiving it. The goal of the implantable devices in yo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Audiology & neuro-otology
دوره 14 5 شماره
صفحات -
تاریخ انتشار 2009