Precision Tests of a Quantum Hall Effect Device DC Equivalent Circuit Using Double-Series and Triple-Series Connections

نویسندگان

  • A. Jeffery
  • R. E. Elmquist
  • M. E. Cage
چکیده

Precision tests verify the dc equivalent circuit used by Ricketts and Kemeny to describe a quantum Hall effect device in terms of electrical circuit elements. The tests employ the use of cryogenic current comparators and the double-series and triple-series connection techniques of Delahaye. Verification of the dc equivalent circuit in double-series and triple-series connections is a necessary step in developing the ac quantum Hall effect as an intrinsic standard of resistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equivalent Electrical Circuit Representations of AC Quantized Hall Resistance Standards

University of Maryland, College Park, MD 20742-4111 We use equivalent electrical circuits to analyze the effects of large parasitic impedances existing in all sample probes on four-terminal-pair measurements of the ac quantized Hall resistance RH. The circuit components include the externally measurable parasitic capacitances, inductances, lead resistances, and leakage resistances of ac quantiz...

متن کامل

Analyzing the Effects of Capacitances-to-Shield in Sample Probes on AC Quantized Hall Resistance Measurements

National Institute of Standards and Technology, Gaithersburg, MD 20899-0001 We analyze the effects of the large capacitances-to-shields existing in all sample probes on measurements of the ac quantized Hall resistance RH. The object of this analysis is to investigate how these capacitances affect the observed frequency dependence of RH. Our goal is to see if there is some way to eliminate or mi...

متن کامل

Mini array of quantum Hall devices based on epitaxial graphene

Series connection of four quantum Hall effect (QHE) devices based on epitaxial graphene films was studied for realization of a quantum resistance standard with an up-scaled value. The tested devices showed quantum Hall plateaux RH,2 at filling factor ν = 2 starting from relatively low magnetic field (between 4 T and 5 T) when temperature was 1.5 K. Precision measurements of quantized Hall resis...

متن کامل

A Problem in AC Quantized Hall Resistance Measurements and a Proposed Solution

In all experiments reported to date the measured values of the ac quantized Hall resistances RH varied with the frequency of the applied current, and differed significantly from the dc values of RH, making it difficult to use the ac quantum Hall effect as an absolute impedance standard. We analyze the effects due to the large capacitances-to-shields existing in the sample probes on measurements...

متن کامل

Introduction and Analysis of a Novel Quasi - Series Resonant DC Link

Soft Switcing techniques have recently been applied in the design of dc-ac converters, in order to achive better performance, higher efficiency, and power density. One of the soft switching techniques uesd in inverters is resonant dc links. These topologies have some disadvantages such as irregular current peaks, large voltage peaks, uncotrollble pulse width, etc. Another soft switching method ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 100  شماره 

صفحات  -

تاریخ انتشار 1995