Automatic Alignment of Renal DCE-MRI Image Series for Improvement of Quantitative Tracer Kinetic Studies

نویسندگان

  • Darko Zikic
  • Steven Sourbron
  • Xinxing Feng
  • Henrik J. Michaely
  • Ali Khamene
  • Nassir Navab
چکیده

Tracer kinetic modeling with dynamic contrast enhanced MRI (DCE-MRI) and the quantification of the kinetic parameters are active fields of research which have the potential to improve the measurement of renal function. However, the strong coronal motion of the kidney in the time series inhibits an accurate assessment of the kinetic parameters. Automatic motion correction is challenging due to the large movement of the kidney and the strong intensity changes caused by the injected bolus. In this work, we improve the quantification results by a template matching motion correction method using a gradient-based similarity measure. Thus, a tedious manual motion correction is replaced by an automatic procedure. The only remaining user interaction is reduced to a selection of a reference slice and a coarse manual segmentation of the kidney in this slice. These steps do not present an overhead to the interaction needed for the assessment of the kinetic parameters. In order to achieve reliable and fast results, we constrain the degrees of freedom for the correction method as far as possible. Furthermore, we compare our method to deformable registration using the same similarity measure. In all our tests, the presented template matching correction was superior to the deformable approach in terms of reliability, leading to more accurate parameter quantification. The evaluation on 10 patient data series with 180-230 images each demonstrate that the quantitative analysis by a two-compartment model can be improved by our method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

Dynamic Contrast-Enhanced MRI of Mouse Liver: A Feasibility Study Using a Dual-Input Two-Compartment Tracer Kinetic Model

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been widely applied to evaluate microcirculatory parameters in clinical settings. However, pre-clinical studies involving DCE-MRI of small animals remain challenging with the requirement for high spatial and temporal resolution for quantitative tracer kinetic analysis. This study illustrates the feasibility of applying a high te...

متن کامل

A synthetic data set for validation of tracer kinetic modelling and model-driven registration in DCE-MRI

G. A. Buonaccorsi, G. J. Parker Imaging science and Biomedical Engineering, University of Manchester, Manchester, Manchester, United Kingdom Introduction In clinical quantitative dynamic contrast enhanced MRI (DCE-MRI), it is difficult to verify the accuracy of estimates of kinetic model parameters such as K, ve and vp, as we do not know the ‘true’ parameter values (ground truth). The problem i...

متن کامل

Evaluation of ve in a Rat Glioma Model with DCE-MRI and Quantitative SPECT

Introduction Dynamic contrast enhanced MRI (DCE-MRI) is used to characterize perfusion and extracellular volume in tumors through the tracer kinetic modeling of MRI contrast agents (typically Gd-DTPA). However, the parametric estimates resultant of DCE-MRI may be influenced by several confounding factors, including inter-compartmental water exchange [1]. In contrast to MRI contrast agents, radi...

متن کامل

Validation of Registration for Renal Dynamic Contrast Enhanced MRI Imaging

In Dynamic Contrast Enhanced Resonance Imaging (DCE-MRI), abdomen is scanned repeatedly and rapidly after injection of a contrast agent. During data acquisition, collected images suffer from the motion induced by the patient if he/she moves or breathes heavily during the scan. Therefore, these images should be aligned accurately to correct the motion. Recently, mutual information (MI) registrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008