Results of a unicentric series of 15 wrist prosthesis implantations at a 5.2 year follow-up.
نویسندگان
چکیده
Our retrospective study aimed to evaluate functional and radiological results of a unicentric series of 17 total wrist prostheses implanted between 2001 and 2011. Nine women and seven men, mean age 59, underwent wrist joint arthroplasty, bilateral in one case. Universal Total Wrist and Remotion prostheses were used and followed-up at a mean of 5.2 years (1.1-10). Fifteen patients were reviewed. Four patients had postoperative complications, three of whom required arthrodesis. The rest obtained satisfactory pain relief. Grip strength nevertheless decreased compared to the contralateral side and mobility was reduced: flexion/extension=33°, ulnar/radial deviation=20°. The Quick DASH score was 29% and PRWE, 26%. Radiological assessment revealed carpal implant loosening in eight patients. Our series confirms the discordance generally observed between patients' subjective satisfaction and mediocre clinical and radiological results over the medium term.
منابع مشابه
MANAGEMENT AND RESULTS OF EXTENSIVE VOLAR WRIST LACERATIONS: “THE SPAGHETTI WRIST“ IN 124 PATIENTS DURING A 5 YEAR PERIOD IN 15TH KHORDAD HOSPITAL TEHRAN
ABSTRACT Background: Spaghetti wrist is a sharp volar wrist laceration in which at least 10 structures, including tendons, at least one major nerve and usually one major vessel are divided. These injuries are usually accompanied with severe permanent complications. The aim of this study was to evaluate the spaghetti wrist injury in Iran and find ways to decrease complications and obtain better...
متن کاملTreatment of Elektra prosthesis complications
Introduction We have been using the Elektra prosthesis for the treatment of osteoarthritis of the CMC joint of the thumb since 1997. After 760 implantations, we studied 689 cases to obtain sufficient follow-up in 596 women and 93 men. Of the 689 cases with sufficient follow up, only 661 cases were not deceased or had records that could be traced. The results in this series are good in terms of ...
متن کاملRadial Head Prosthesis Removal:a Retrospective Case Series of 14 Patients
Background: The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis. Methods: This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 month...
متن کاملOutcome Assessment after Aptis Distal Radioulnar Joint (DRUJ) Implant Arthroplasty
Background: Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ) such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna. The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthro...
متن کاملStudy of Median Palmar Cutaneous Nerve Involvement in a Patient with Wrist Ganglion
Background: Few reports represent palmar cutaneous nerve neuropathy in the wrist due to a ganglion cyst. Case Presentation: A 25-year-old female was presented with a mass at volar side of the wrist and hypoesthesia at the base of thenar eminence. At ulrasonographic examination, a simple cyst was detected. Sensory response of palmar cutaneous branch of median nerve was absent at the affec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 82 1 شماره
صفحات -
تاریخ انتشار 2016