This study examined the axial and torsional stiffness of polyaxial locked plating techniques compared with fixed-angle locked plating techniques in a distal tibia pilon fracture model. The effect of using a polyaxial screw to cross the fracture site was examined to determine its ability to control relative fracture site motion. A laboratory experiment was performed to investigate the biomechanical stiffness of distal tibia fracture models repaired with 3.5-mm anterior polyaxial distal tibial plates and locking screws. Sawbones Fourth Generation Composite Tibia models (Pacific Research Laboratories, Inc, Vashon, Washington) were used to model an Orthopaedic Trauma Association 43-A1.3 distal tibia pilon fracture. The polyaxial plates were inserted with 2 central locking screws at a position perpendicular to the cortical surface of the tibia and tested for load as a function of axial displacement and torque as a function of angular displacement. The 2 screws were withdrawn and inserted at an angle 15° from perpendicular, allowing them to span the fracture and insert into the opposing fracture surface. Each tibia was tested again for axial and torsional stiffness. In medial and posterior loading, no statistically significant difference was found between tibiae plated with the polyaxial plate and the central screws placed in the neutral position compared with the central screws placed at a 15° position. In torsional loading, a statistically significant difference was noted, showing greater stiffness in tibiae plated with the polyaxial plate and the central screws placed at a 15° position compared with tibiae plated with the central screws placed at a 0° (or perpendicular) position. This study showed that variable angle constructs show similar stiffness properties between perpendicular and 15° angle insertions in axial loading. The 15° angle construct shows greater stiffness in torsional loading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Master Techniques in Orthopaedic Surgery: Fractures

This edition includes ten new chapters – total elbow arthroplasty, revised shoulder arthroplasty, proximal humerus hemiarthroplasty, extra articular proximal tibial fractures, submuscularis locked plating, subtrochanteric femur fractures, ankle fractures, calcaneal fractures, tibial pilon fractures, and staged ORIF. Seventeen chapters have been rewritten by new contributing authors and leaders ...

متن کامل

Master Techniques in Orthopaedic Surgery: Fractures

This edition includes ten new chapters – total elbow arthroplasty, revised shoulder arthroplasty, proximal humerus hemiarthroplasty, extra articular proximal tibial fractures, submuscularis locked plating, subtrochanteric femur fractures, ankle fractures, calcaneal fractures, tibial pilon fractures, and staged ORIF. Seventeen chapters have been rewritten by new contributing authors and leaders ...

متن کامل

Master Techniques in Orthopaedic Surgery: Fractures

This edition includes ten new chapters – total elbow arthroplasty, revised shoulder arthroplasty, proximal humerus hemiarthroplasty, extra articular proximal tibial fractures, submuscularis locked plating, subtrochanteric femur fractures, ankle fractures, calcaneal fractures, tibial pilon fractures, and staged ORIF. Seventeen chapters have been rewritten by new contributing authors and leaders ...

متن کامل

Master Techniques in Orthopaedic Surgery: Fractures

This edition includes ten new chapters – total elbow arthroplasty, revised shoulder arthroplasty, proximal humerus hemiarthroplasty, extra articular proximal tibial fractures, submuscularis locked plating, subtrochanteric femur fractures, ankle fractures, calcaneal fractures, tibial pilon fractures, and staged ORIF. Seventeen chapters have been rewritten by new contributing authors and leaders ...

متن کامل

Results in treatment of distal femur fractures using polyaxial locking plate

Indications and techniques of locked plate fixation for the treatment of challenging fractures continue to evolve. As design variant of classic locked plates, the polyaxial locked plate has the ability to alter the screw angle and thereby, enhance fracture fixation. The aim of this observational study was to evaluate clinical and radiographic results in 89 patients with 90 fractures of the dist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 8  شماره 

صفحات  -

تاریخ انتشار 2015