Silicone migration to the contralateral axillary lymph nodes and breast after highly cohesive silicone gel implant failure: a case report

نویسندگان

  • Gabriel J Kaufman
  • Rita A Sakr
  • Cyrille Inguenault
  • Isabelle Sarfati
  • Claude Nos
  • Krishna B Clough
چکیده

Highly cohesive silicone gel implants are advertised for aesthetic and safety advantages. Our case is the fourth report describing early implant rupture and contralateral migration of siliconoma. Despite the greater degree of gel cohesiveness, a continued vigilance for signs and symptoms of migration is highly recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contralateral intramammary silicone lymphadenitis in a patient with an intact standard dual-lumen breast implant in the opposite reconstructed breast.

Silicone lymphadenopathy is a recognized complication of silicone gel implant rupture; the ipsilateral axillary lymph nodes are most commonly involved. We report imaging findings on a range of different imaging modalities and biopsy results in a case of biopsy-proven silicone lymphadenitis involving contralateral intramammary and axillary lymph nodes in a patient with an intact standard dual-lu...

متن کامل

Neck lymphadenitis due to silicone granuloma after mammary implants.

INTRODUCTION A foreign body reaction due to silicone where it is infiltrated or at the places to which it can migrate is known as siliconoma. The use of silicone in breast augmentation procedures can provoke this reaction at the neck level in cases of leakage from mammary implants. METHODS We reviewed the cases of patients with increased size neck lymph nodes who had previously undergone plas...

متن کامل

Neck Lymphadenitis Due to Silicone Granuloma After Mammary Implants

Introduction: A foreign body reaction due to silicone where it is infiltrated or at the places to which it can migrate is known as siliconoma. The use of silicone in breast augmentation procedures can provoke this reaction at the neck level in cases of leakage from mammary implants. Methods: We reviewed the cases of patients with increased size neck lymph nodes who had previously undergone plas...

متن کامل

Axillary silicone lymphadenopathy presenting with a lump and altered sensation in the breast: a case report

INTRODUCTION Silicone lymphadenopathy is a rare but recognised complication of procedures involving the use of silicone. It has a poorly understood mechanism but is thought to occur following the transportation of silicone particles from silicone-containing prostheses to lymph nodes by macrophages. CASE PRESENTATION We report of a case involving a 35-year-old woman who presented to the breast...

متن کامل

Distant Migration of Multiple Siliconomas in Lower Extremities following Breast Implant Rupture: Case Report

Siliconoma from ruptured breast implants has been reported in multiple body sites, including but not limited to the breast parenchyma, axillary lymph nodes, upper arm, and even lower leg. In this regard, we report a rare case of distant silicone migration to the lower extremities after traumatic breast implant rupture. A 55-year-old Asian woman who received bilateral augmentation mammoplasty 20...

متن کامل