Scaling the EIT Problem

نویسندگان

  • Alistair Boyle
  • Andy Adler
  • Andrea Borsic
چکیده

There are a number of interesting problems that could be tackled if the computing capacity of current EIT systems can be improved. We examined the performance of two such systems and found that a noticeable portion of the compute time is spent in finding the solution of sparse matrices. We developed and used a new sparse matrix testbench, Meagre-Crowd, to evaluate a selection of these sparse matrix solvers and found that there are definite performance gains available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using shifted Legendre scaling functions for solving fractional biochemical reaction problem

In this paper, biochemical reaction problem is given in the form of a system of non-linear differential equations involving Caputo fractional derivative. The aim is to suggest an instrumental scheme to approximate the solution of this problem. To achieve this goal, the fractional derivation terms are expanded as the elements of shifted Legendre scaling functions. Then, applying operational matr...

متن کامل

Comparison of 3D Image Reconstruction Techniques using Real Electrical Impedance Measurement Data

The present status of electrical impedance tomography (EIT) is such that many successful laboratory based studies and pilot plant demonstrators are generating interest in developing the technology. However, while the EIT problem is inherently 3D, many studies make 2D assumptions in order to simplify the problem. Proportionately less work has been carried out on the true 3D EIT problem, outside ...

متن کامل

Continuous Nondestructive Monitoring Method Using the Reconstructed Three-Dimensional Conductivity Images via GREIT for Tissue Engineering

A continuous non-destructive monitoring method is required to apply proper feedback controls during tissue regeneration. Conductivity is one of valuable information to assess the physiological function and structural formation of regenerated tissues or cultured cells. However, conductivity imaging methods are suffered from inherited ill-posed characteristics in image reconstruction, unknown bou...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Image Reconstruction using Simulated Annealing Algorithm in EIT

In electrical impedance tomography (EIT), various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically, the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. This paper presents a simulated annealing technique as a statistical reco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011