Atomic absorption spectrometric determination of selenium in human blood components.

نویسندگان

  • L Hansson
  • J Pettersson
  • L Eriksson
  • A Olin
چکیده

We separated blood from five healthy blood donors into plasma, erythrocytes, platelets, and leukocytes; counted the number of cells in each fraction; and determined the selenium content of each component by hydride generation atomic absorption spectrometry. The mean (+/- SD) selenium concentrations and amounts measured were as follows: whole blood 102.3 +/- 16.1 micrograms/L, plasma 76.9 +/- 10.6 micrograms/L, erythrocytes 13.7 +/- 2.8 ag per cell, platelets 4.8 +/- 1.1 ag per cell, and leukocytes 99 +/- 26 ag per cell.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atomic Absorption Spectrometric Determination of Lead after Extraction and Preconcentration with 5-Br-PADAP

Lead is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 4.0-6.0 from a large volume of aqueous solutions of various samples with preconcentration factor of 60. After filtration, the solid mass consisting of the lead complex and naphthalene was dissolved wi...

متن کامل

Flame atomic absorption spectrometric determination of Cd(II), Zn(II) and Ag(I) in different matrixes after solid phase extraction on sodium dodecyl sulfate (SDS)-coated alumina as their 2,3 Di Hydro 2,3 para tolyl Qinazoline (1 H)- 4 one (DPTQO)

A sensitive and selective solid phase extraction procedure for the determination of traces of Cd(II),Zn(II) and Ag(I) ions has been developed. An alumina-sodium dodecyl sulfate (SDS) coated on with2,3 Di Hydro 2,3 para tolyl Qinazoline (1 H)- 4 one (DPTQO). The influences of the analyticalparameters including pH and sample volume were investigated. Common coexisting ions did notinterfere on the...

متن کامل

Improved determination of selenium in serum by Zeeman atomic absorption spectrometry.

We have improved Zeeman atomic absorption spectrometric determination of selenium in serum by using an acidic solution of Ag + Cu + Mg as a matrix modifier and performing the charring step in flowing O2. Under these conditions, we could calibrate serum results with selenium standards in bovine albumin solutions. Mean analytical recovery was 98%, and the CV was 1.8% within runs, 2.9% between run...

متن کامل

GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER

An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...

متن کامل

Separation and speciation of selenium in food and water samples by the combination of magnesium hydroxide coprecipitation-graphite furnace atomic absorption spectrometric determination.

A simple and economic separation and speciation procedure for selenium in food and water samples have been presented prior to its graphite furnace atomic absorption spectrometry (GFAAS). Magnesium hydroxide coprecipitation system for selenium(IV) was applied to the separation and speciation of selenium ions. The influences of the various analytical parameters for the quantitative recoveries of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 1989