Cerebral monitoring during carotid endarterectomy--a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure.

نویسندگان

  • K Botes
  • D A Le Roux
  • J Van Marle
چکیده

OBJECTIVE Various modalities are used for cerebral monitoring during carotid endarterectomy (CEA). The aim of this study was to evaluate whether transcranial cerebral oximetry (TCO) and carotid stump pressure (SP) are as accurate as electroencephalography (EEG) for monitoring cerebral ischaemia during carotid cross-clamping. METHODS One hundred consecutive patients who underwent CEA were studied with continuous and simultaneous EEG and TCO. SP was measured for each patient. The percentage decrease of oxygenation on TCO was calculated during cross-clamping and surgery. EEG findings were used as the benchmark to detect cerebral ischaemia and were the indication for insertion of a temporary shunt. The relationship with TCO was observed in terms of percentage decrease in oxygenation. RESULTS A total of 6 patients were shunted on the basis of their EEG changes. TCO changed more than 20% in these 6 patients, but an additional 12 patients had TCO changes with a normal EEG. This correlated with a decrease in blood pressure (BP) and was corrected by increasing the BP. The positive predictive values (PPVs) and negative predictive values (NPVs) for shunting based on TCO (as compared with EEG) were 33% and 100% respectively. Thirty-four patients had SP <50 mmHg, of whom 4 were shunted based on EEG changes. Two of 66 patients with SP >50 mmHg were shunted based on EEG changes. If a shunting policy had been based on a SP of 50 mmHg, 30 patients would have been shunted unnecessarily (PPV 12%), whereas the non-requirement for a shunt was predicted correctly in 64 of 66 patients (NPV 97%). There were 2 major strokes: 1 contralateral on day 3 in a patient with bilateral severe stenoses, and 1 ipsilateral in a nonshunted patient with normal EEG, TCO and SP >50 mmHg. CONCLUSION Compared with EEG, TCO is a practical and non-invasive monitoring system with a high sensitivity (100%) but a low specificity. TCO is more sensitive to a drop in BP and responds earlier to these changes than EEG. SP should not be used as the sole predictor for shunting during CEA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relation between middle cerebral artery blood flow velocity and stump pressure during carotid endarterectomy.

BACKGROUND AND PURPOSE Many patient monitoring techniques have been used for detecting cerebral hypoperfusion during carotid endarterectomy. We compared middle cerebral artery blood flow velocities with carotid artery stump pressures to evaluate the indications for common carotid artery cross-clamp shunting and the probable hemodynamic causes of cerebrovascular complications. METHODS Blood fl...

متن کامل

Monitoring cerebral ischemia during carotid endarterectomy and stenting

Current therapy for carotid stenosis mainly includes carotid endarterectomy and endovascular stenting, which may incur procedure-related cerebral ischemia. Several methods have been employed for monitoring cerebral ischemia during surgery, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectrosc...

متن کامل

Dual Monitoring with Stump Pressure and Electroencephalography During Carotid Endarterectomy

BACKGROUND Intraoperative monitoring during carotid endarterectomy is crucial for cerebral protection. We investigated the results of carotid endarterectomy under dual monitoring with stump pressure and electroencephalography. METHODS We retrospectively reviewed the medical records of 50 patients who underwent carotid endarterectomy between March 2010 and February 2016. We inserted a temporar...

متن کامل

Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.

BACKGROUND This study compares the accuracy of cerebral monitoring systems in detecting cerebral ischemia during carotid endarterectomy. METHODS The authors compared transcranial Doppler sonography (TCD), near-infrared spectroscopy (NIRS), stump pressure (SP) measurement, and somatosensory evoked potentials (SEP) in 48 patients undergoing carotid surgery during regional anesthesia. Cerebral i...

متن کامل

Peroperative neuromonitoring during carotid endarterectomy in relation to preoperative positron emission tomography findings.

OBJECTIVES To compare stump pressure (SP), transcranial Doppler (TCD), electroencephalography (EEG) and selective shunting during carotid endarterectomy (CEA) with preoperative positron emission tomography (PET) parameters. MATERIALS AND METHODS Preoperative PET measurements and peroperative neuromonitoring were performed in ten patients undergoing CEA for symptomatic carotid artery disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • South African journal of surgery. Suid-Afrikaanse tydskrif vir chirurgie

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2007