Effect of Flip Angle on the Correlation Between Signal Intensity and Different Concentrations of Iron Oxide Nanoparticles Using T1-Weighted Turbo-FLASH Inversion Recovery Sequence
نویسندگان
چکیده
BACKGROUND Ultrasmall superparamagnetic iron oxide nanoparticles have been used as a blood pool contrast agent for magnetic resonance angiography and perfusion studies. Linear relationship between signal intensity (SI) and nanoparticle concentration is essential for perfusion measurement. OBJECTIVES The aim of this study was to investigate the effect of different flip angles on maximum SI and the linear relationship between SI and different concentrations of iron oxide nanoparticles using T1-weighted Turbo-FLASH (fast low angle shot) inversion recovery sequence to find the optimum flip angle for perfusion measurement. MATERIALS AND METHODS This in vitro study was performed using carboxydextran coated iron oxide nanoparticles with 20 nm hydrodynamic size. Different concentrations of nanoparticles between 0 and 500 µmol Fe/L were prepared. MR imaging was performed using T1-weighted Turbo-FLASH inversion recovery sequence. Applied flip angles were 10-45º (interval of 5º). Then the maximum SI resulted by each concentration of nanoparticles was measured. Linear relationship between SI and nanoparticle concentration was evaluated regarding square correlations of 0.95 and 0.99. Coil non-uniformity was considered to obtain accurate SI of each image. RESULTS The maximum SI was obtained at the highest applied flip angle (45°). The linear relationship between SI and nanoparticle concentration was seen up to 112.21 and 98.83 μmol Fe/L for the short (10°) and the long (45°) flip angles, respectively (R(2) = 0.95). These values were reduced up to 48.54 and 42.73 μmol Fe/L for these flip angles with R(2) of 0.99. CONCLUSIONS The maximum SI will be increased at higher flip angles with non-linear relationship between SI and nanoparticle concentration. The result shows that an increase in the flip angle leads to a decrease in the range of the linearity. The optimum flip angle which is suitable for perfusion measurement was obtained at 10º for our imaging parameters and sequence. The results of this study may be used in in vivo perfusion measurements.
منابع مشابه
Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inver-sion recovery T1-weighted MRI
Background: Ultrasmallsuperparamagnetic iron oxide (USPIO) nanoparticles are used as blood pool contrast agent for magnetic resonance angiography and perfusion imaging. Our aim in this study was to investigate the effect of the two coating types of iron oxide nanoparticles on the relationship between nanoparticles concentration and signal intensity (SI) in T1-weighted MR images. Methods : D...
متن کاملاثر زمان معکوس بر ارتباط خطی بین غلظت نانوذرات اکسید آهن با پوشش پلی اتیلن گلیکول و شدت سیگنال در تصویربرداری تشدید مغناطیسی با سکانس بازیافت معکوس
Background and purpose: In MRI the concentration of contrast agent is indirectly measured from signal intensity (SI). It is important to find the maximum linear relationship between SI and concentration of the iron oxide nanoparticles for perfusion measurement. The aim of this study was to investigate the effect of inversion time on SI and the maximum linear relationship between SI and concentr...
متن کاملEffect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inversion recovery T1-weighted MRI
BACKGROUND Ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles are used as blood pool contrast agent for magnetic resonance angiography and perfusion imaging. Our aim in this study was to investigate the effect of the two coating types of iron oxide nanoparticles on the relationship between nanoparticles concentration and signal intensity (SI) in T1-weighted MR images. METHODS Diffe...
متن کاملThe effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملThe Effect of Inversion Time on the Relationship Between Iron Oxide Nanoparticles Concentration and Signal Intensity in T1-Weighted MR Images
BACKGROUND Magnetic nanoparticles have been widely applied in recent years for biomedical applications. Signal intensity (SI) of magnetic resonance (MR) images depends on the concentration of nanoparticles. It is important to find the minimum concentration of iron oxide nanoparticles that produces maximum SI and determines the minimum injection dose for clinical studies. OBJECTIVES This study...
متن کامل