Trading spectral separation at 3T for acquisition speed in multi spin-echo spectroscopic imaging.

نویسندگان

  • U Dydak
  • D Meier
  • R Lamerichs
  • P Boesiger
چکیده

Fast multiple spin-echo spectroscopic imaging, also called turbo spectroscopic imaging (TSI), may be enhanced in terms of acquisition speed by taking advantage of the higher spectral separation afforded at higher field strength and by further combining it with sensitivity encoding (SENSE). This article demonstrates the possibilities of this approach at 3T, resulting in scan-time reductions of up to a factor of 10. High-resolution, in vivo, single- and multiple-section spectroscopic imaging data are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Echo-Based Echo-Planar Spectroscopic Imaging Using a 3T MRI Scanner

The use of spin-echoes has been employed in an Echo-Planar Spectroscopic Imaging (EPSI) sequence to collect multiple phase encoded lines within a single TR in a Multi-Echo-based Echo-Planar Spectroscopic Imaging technique (MEEPSI). Despite the T₂ dependence on the amplitude of the spin-echoes, the Full Width at Half Maximum (FWHM) of the derived multi-echo Point Spread Function (PSF) is shown t...

متن کامل

Fast MR Spectroscopic Imaging

MR spectroscopic imaging (MRSI) has become widely available as a research tool for mapping tissue metabolic status. Clinical research applications have been limited by intrinsically low sensitivity and by time-consuming phase encoding techniques that are used with conventional MRSI. The long encoding times limit volume coverage, introduce motion sensitivity and tax patient tolerance. The increa...

متن کامل

Spin-Echo planar spectroscopic imaging for fast lipid characterization in bone marrow.

Lipid characterization of bone marrow in vivo with proton magnetic resonance spectroscopy was performed using Spin-Echo Planar Spectroscopic Imaging sequences. The methods are shown capable of rapidly generating two-dimensional chemical shift imaging data sets suitable for measuring lipid indices that reflect unsaturation levels among triglycerides, as demonstrated in oil phantoms and bone marr...

متن کامل

High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding.

Prostate MR spectroscopic imaging (MRSI) at 3T may provide two-fold higher spatial resolution over 1.5T, but this can result in longer acquisition times to cover the entire gland using conventional phase-encoding. In this study, flyback echo-planar readout trajectories were incorporated into a Malcolm Levitt's composite-pulse decoupling sequence (MLEV)-point-resolved spectroscopy sequence (PRES...

متن کامل

Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3T.

Proton MR spectroscopic imaging ((1)H-MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 27 7  شماره 

صفحات  -

تاریخ انتشار 2006