Clinical Significance of Scintillation Camera Electronics

نویسنده

  • Wayne Thompson
چکیده

Recent advances in collimator design and detector size, combined with radiopharmaceuticals having high photon yield, have resulted in diagnostic tests that may deliver photon fluxes in excess of the levels at which scintillation cameras can process the data. Moreover, these high rates of photon input may im pair certain parameters of image quality (1 ,2). For certain diagnostic tests, such as cardiac flows, input rates can exceed 300,000 cps. The observed count rate is not indicative of the input rate during such clinical tests because of variable scatter fractions and nonconstant deadtimes for scintillation cameras (3,4) . Some of the more recent models of the Anger scintillation camera use new electronic designs that allow count rate processing capabilities up to 200,000 cps (5), a level that approaches the needs of standard diagnostic tests in nuclear medicine. The

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Quantitative Evaluation of Scintillation Camera Imaging Characteristics of Isotopes Used in Liver Radioembolization

BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...

متن کامل

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

Quality Control of Scintillation Cameras (Planar and SPECT)

The purpose of quality control (QC) is to detect changes in the performance of a gamma camera system that may adversely affect the interpretation of clinical studies. Clearly, there are a large number of factors that contribute to the final image quality, including uniformity, resolution (both intrinsic and energy), collimation and the hard copy device. In addition, for certain types of studies...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006