SU-E-T-612: Hybrid-Input-Output Algorithm for IMRT Optimization with Dose-Volume Histogram Constraints.
نویسندگان
چکیده
PURPOSE Dose-volume histogram (DVH) is a clinically relevant criterion to evaluate a treatment plan quality. It is hence desirable to incorporate DVH constraints in treatment planning process for intensity modulated radiation therapy (IMRT). Yet, these constraints usually lead to difficulties due to their non-convex nature. The purpose of this project is to solve the IMRT optimization problem with DVH constraints using a hybrid-input-output (HIO) method. METHODS The IMRT optimization problem finds a dose distribution z under two constraints, where the elements of the vector z are the dose value at each spatial coordinate. First, there exist a corresponding fluence map x such that Dx=z and x>0, where D is the dose deposition matrix. Second, the dose distribution z should satisfy the DVH constraints. These two constraints define two sets of the dose distributions, denoted by A and B, and the solution to the IMRT problem lies in the intersection of these two sets. Our method finds the solution via the HIO algorithm that iteratively updates the solution according to its projections onto the two sets until convergence. The projection to A is handled by solving a least square problem and the projection to B is achieved by gradually adjusting voxel doses that validate the DVH criteria to meet the constraints. RESULTS We have tested our algorithm using 7-field IMRT plans for 4 prostate cancer cases. Clinically relevant DVH constraints are considered for PTV, rectum, and bladder. In all the cases, the algorithm is able to find the solutions that satisfy all the DVH constraints. CONCLUSIONS We have developed an algorithm to solve the IMRT optimization problem with DVH constraints using the HIO approach. Tests conducted in prostate cancer cases have demonstrated the effectiveness of our algorithm.
منابع مشابه
Advanced Optimization Laboratory Title: Controlling the dose distribution with gEUD-type constraints within the convex IMRT optimization framework
Radiation therapy is an important modality in treating various cancers. Various treatment planning and delivery technologies have emerged to support Intensity Modulated Radiation Therapy (IMRT), creating significant opportunities to advance this type of treatment. We investigate the possibility of including the dose prescription, specified by the Dose Volume Histogram (DVH), within the convex o...
متن کاملControlling the dose distribution with gEUD-type constraints within the convex IMRT optimization framework
Radiation therapy is an important modality in treating various cancers. Various treatment planning and delivery technologies have emerged to support Intensity Modulated Radiation Therapy (IMRT), creating significant opportunities to advance this type of treatment. We investigate the possibility of including the dose prescription, specified by the Dose Volume Histogram (DVH), within the convex o...
متن کاملThe effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT
Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans. Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...
متن کاملThree-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
متن کاملDosimetric impact of intermediate dose calculation for optimization convergence error
Intensity-modulated radiation therapy (IMRT) provides the protection of the normal organs and a precise treatment plan through its optimization process. However, the final dose-volume histogram (DVH) obtained by this technique differs from the optimal DVH, owing to optimization convergence errors. Herein, intermediate dose calculation was applied to IMRT plans during the optimization process to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part19 شماره
صفحات -
تاریخ انتشار 2012