P 446 Measuring time delays in colour vision using the Pulfrich effect
نویسندگان
چکیده
m In the detection of color vision deficiencies, the focus is not only on the disturbed color axis, but also on the degree of disturbed color vision. Therefore, in order to find out the normal sum of errors, we evaluated this color test in a normal population. Methods: 95 subjects (m:f=71:24) without any ocular or general chronic disease were tested monocularly with tie desaturated Roth 26 HUE color test (Luneau, Paris) under standard conditions. The background was a black cardboard, the illumination consisted of two fluorescent lamps (Osram Li 6W/ll, Germany) with 6000 Kelvin. The subjects were divided into 4 different age groups: O-19, 20-39, 40-59 and 60-79. The quantitative analysis was done using a specially developed software (M.A.) on an IBM compatible computer. Results: In the ophthalmic examination, no functional or morphological abnormalities werefound. In general, the mean sum of errors was 66 * 35 (Minimum 0, Maximum 174; Median 60). There were no differences between the right or left eye (p=O,6, MannWhitney test), nor between male and female (p=O,64, Mann-Whitney test). No correlation was found between age and sum of errors (regression coefficient=0,027; p=O,94). Conclusion: Based on these data, the desaturated Roth 26 HUE test seems to be a color test with a stable sum of errors over the age. Therefore, this test can now be used in the follow-up of color disturbances, caused for example by chronic drug application or by chronic diseases. In addition, this test is quicker than the Farnsworth Munsell 100 HUE test and therefore less dependent of the patient’s vigilance. P447
منابع مشابه
The effect of interocular delay on disparity - selective V 1 neurons : relationship to stereoacuity and the Pulfrich effect
Szarowicz and Chris Hillman for excellent animal care. Abstract The temporal properties of disparity-sensitive neurons place important temporal constraints on stereo matching. We examined these constraints by measuring the responses of disparity-selective neurons in striate cortex of awake behaving monkeys to random dot stereograms that contained interocular delays. Disparity selectivity was gr...
متن کاملRetinal adaptation of visual processing time delays.
A significant proportion of the processing delays within the visual system are luminance dependent. Thus placing an attenuating filter over one eye causes a temporal delay between the eyes and thus an illusion of motion in depth for objects moving in the fronto-parallel plane, known as the Pulfrich effect. We have used this effect to study adaptation to such an interocular delay in two normal s...
متن کاملEffect of interocular delay on disparity-selective v1 neurons: relationship to stereoacuity and the pulfrich effect.
The temporal properties of disparity-sensitive neurons place important temporal constraints on stereo matching. We examined these constraints by measuring the responses of disparity-selective neurons in striate cortex of awake behaving monkeys to random-dot stereograms that contained interocular delays. Disparity selectivity was gradually abolished by increasing interocular delay (when the dela...
متن کاملThe rotating Pulfrich effect, and a new method of determining visual latency differences.
A rotating Pulfrich effect is described and analysed in relation to the Fertsch-Pulfrich latency difference theory. Although some of the predictions conflicted with observations described by Pulfrich [Naturwissenschaften 10, 553-564 (1922)], they were confirmed by experiment, and led to a simple and sensitive method of determining visual latency differences.
متن کاملSmall-Aperture Monovision and the Pulfrich Experience: Absence of Neural Adaptation Effects
PURPOSE To explore whether adaptation reduces the interocular visual latency differences and the induced Pulfrich effect caused by the anisocoria implicit in small-aperture monovision. METHODS Anisocoric vision was simulated in two adults by wearing in the non-dominant eye for 7 successive days, while awake, an opaque soft contact lens (CL) with a small, central, circular aperture. This was r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 35 شماره
صفحات -
تاریخ انتشار 1995