Drug testing in oral fluid-evaluation of sample collection devices.

نویسندگان

  • Kaarina Langel
  • Charlotta Engblom
  • Anna Pehrsson
  • Teemu Gunnar
  • Kari Ariniemi
  • Pirjo Lillsunde
چکیده

Nine different oral fluid (OF) collection devices were studied to evaluate their suitability for collecting samples for drug analysis. The devices were Greiner Bio-One, Orasure Intercept, Immunalysis Quantisal, StatSure Saliva.Sampler, Cozart, Sarstedt Salivette, Malvern Medical OraCol, Acro Biotech Salicule, and Varian OraTube. For comparison, OF was also collected into plastic tubes. The volume of collected OF was quantified for samples collected both in vitro and from volunteers. Drug recovery was studied by collecting OF fortified at 1000 ng/mL with amphetamine, 3,4-methylenedioxymethamphetamine, cocaine, Delta(9)-tetrahydrocannabinol, morphine, codeine, diazepam, and alprazolam with the devices in vitro and analyzing the samples with gas chromatography-mass spectrometry. Recovery of ethanol was measured from 0.2% in OF by headspace gas chromatography-flame-ionization detection. The stability of drugs in the samples was studied by analyzing the samples after 0, 14, and 28 days storage. The study shows that there are substantial differences between the OF collection devices on the market. Some are well suited for collecting samples for toxicological analysis, but some give quite poor results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current technologies and considerations for drug bioanalysis in oral fluid.

Drug oral fluid analysis was first used almost 30 years ago for the purpose of therapeutic drug monitoring. Since then, oral fluid bioanalysis has become more popular, mainly in the fields of pharmacokinetics, workplace drug testing, criminal justice, driving under the influence testing and therapeutic drug monitoring. In fact, oral fluid can provide a readily available and noninvasive medium, ...

متن کامل

Development and validation of the Cozart DDS oral fluid collection device.

The testing of oral fluid for drugs of abuse has increased significantly over recent years and is now commonplace in drug rehabilitation clinics, the workplace, prisons and custody suites. The global problem of identifying drugged drivers has also led to an increase in oral fluid testing at the roadside. The main requirements for the implementation of roadside drug testing are a rapid sample co...

متن کامل

An evaluation of rapid point-of-collection oral fluid drug-testing devices.

New technology is currently being marketed to rapidly test oral fluids for drugs of abuse at the point of collection (POC). There are no nationally accepted standards or cutoff concentrations for detecting drugs in oral fluids and for most analytes there are significant differences in cutoff concentrations across devices. Four devices were evaluated (OralLab), RapiScan, Drugwipe, and SalivaScre...

متن کامل

Evaluation of ten oral fluid point-of-collection drug-testing devices.

Previously, the laboratory evaluations of six point-of-collection oral fluid (POC-OF) drug testing devices were reported. Four additional devices, Oralstat (American Bio Medica); SmartClip (Envitec); Impact (LifePoint); and OraLine IV s.a.t (Sun Biomedical Laboratories), were recently evaluated for their ability to meet the claimed (and proposed) cutoff concentrations set by the manufacturers f...

متن کامل

Oral fluid collection: the neglected variable in oral fluid testing.

The potential to use oral fluid as a drug-testing specimen has been the subject of considerable scientific interest. The ease with which specimens can be collected and the potential for oral fluid (OF) drug concentrations to reflect blood-drug concentrations make it a potentially valuable specimen in clinical as well as forensic settings. However, the possible effects of the OF collection proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 32 6  شماره 

صفحات  -

تاریخ انتشار 2008