Total endoscopic computer enhanced coronary artery bypass grafting.

نویسندگان

  • V Falk
  • A Diegeler
  • T Walther
  • J Banusch
  • J Brucerius
  • J Raumans
  • R Autschbach
  • F W Mohr
چکیده

OBJECTIVE In an effort to minimize access in coronary artery bypass (CAB) surgery, a total endoscopic approach using computer enhanced technology was developed. METHODS By July 1999 the da Vinci telemanipulation system (Intuitive Surgical, Mountain View, CA) was used in 66 patients with coronary artery disease. In 12 patients undergoing routine coronary artery bypass grafting (CABG) (group 1) the internal thoracic artery (ITA) to left anterior descending artery (LAD) anastomosis was performed remotely using the system. In 32 patients (group 2) endoscopic dissection of the ITA was performed followed by a conventional minimally invasive direct coronary artery bypass (MIDCAB) operation. In 22 patients (group 3) the complete operation was performed endoscopically through 4 ports (total endoscopic coronary artery bypass, TECAB). Port-Access cardiopulmonary bypass with cardioplegic arrest was used for TECAB. RESULTS In group 1 the time for performing the ITA to LAD anastomosis was 17 +/- 10 min. Mean graft flow was 38 +/- 25 ml/min. One anastomosis leaked and was repaired manually. In group 2 in 31/32 patients (96%) the ITA harvest was successfully performed with the system at mean of 61 +/- 27 min. There was a substantial learning curve associated with ITA take-down. In one patient a dissection caused insufficient free ITA graft flow which necessated additional vein grafting. Postoperative angiography demonstrated graft patency in all cases. In the TECAB group, the operation could be completed through four ports in 18 of the 22 patients (82%) with operating times in the range 220-507 min. In four patients, elective conversion to a minithoracotomy was required due to failure to identify the LAD (1), bleeding from the anastomosis (1), grafting of a diagonal branch (1) and torsion of the pedicle (1). One patient required reoperation for bleeding from an ITA side-branch. Median intubation time was 13 h and stay on ICU and hospitalization were 20 h and 7 days, respectively. A 3-month follow-up angiography revealed patent grafts in all TECAB patients. CONCLUSION Endoscopic ITA harvesting and performing of arterial anastomoses can be safely performed with the da Vinci system. TECAB is possible on the arrested heart with good functional results. However, a substantial learning curve has to be overcome which is reflected in long operation times and an initial significant conversion rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wrist-enhanced instrumentation: moving toward totally endoscopic coronary artery bypass grafting.

BACKGROUND With the introduction of the da Vinci robotic surgical system (Intuitive Surgical, Mountain View, CA) into minimally invasive cardiac operations the outlook for performing coronary artery bypass operations "closed chest" became a reality. METHODS Between May 1999 and December 1999 this new wrist-enhanced instrumentation was used in 61 patients. Six patients suffering from single-ve...

متن کامل

پیوند عروق کرونر

  This article describes coronary artery bypass grafting by Avlliath Jay akrishnan et al. one of the most common reason for coronary artery bypass grafting is narrowing coronary arteries because of atherosclerosis. Atherosclerosis causes chest pain (angina pectoris), myocardial infarction and sudden death. The aim of coronary artery bypass grafting is to release pain, prevention of myocardial i...

متن کامل

Pii: S1569-9293(02)00008-7

Telemanipulators have been introduced into cardiac surgery recently expanding the scope of minimally invasive techniques and enabling endoscopic cardiac surgery. Our aim was to evaluate clinical results of totally endoscopic single vessel bypass grafting on the arrested as well as on the beating heart. Since 1999, 44 totally endoscopic single vessel arterial bypass grafting procedures were perf...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Endoscopic radial artery harvesting procedure for coronary artery bypass grafting.

Development and adoption of endoscopic minimally invasive saphenous vein harvesting prompted its application to the radial artery in an effort to minimize surgical trauma. Recently, we reported that endoscopic radial artery harvesting was associated with better wound appearance and it proved to be safe and effective, with less pain and fewer wound complications than the open surgical technique....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2000