Scaling of maximum net force output by motors used for locomotion.
نویسنده
چکیده
Biological and engineered motors are surprisingly similar in their adherence to two or possibly three fundamental regimes for the mass scaling of maximum force output (Fmax). One scaling regime (Group 1: myosin, kinesin, dynein and RNA polymerase molecules; muscle cells; whole muscles; winches; linear actuators) comprises motors that create slow translational motion with force outputs limited by the axial stress capacity of the motor, which results in Fmax scaling as motor mass0.67 (M0.67). Another scaling regime (Group 2: flying birds, bats and insects; swimming fish; running animals; piston engines; electric motors; jets) comprises motors that cycle rapidly, with significant internal and external accelerations, and for whom inertia and fatigue life appear to be important constraints. The scaling of inertial loads and fatigue life both appear to enforce Fmax scaling as M1.0 in these motors. Despite great differences in materials and mechanisms, the mass specific Fmax of Group 2 motors clusters tightly around a mean of 57 N kg(-1), a region of specific force loading where there appears to be a common transition from high- to low-cycle fatigue. For motors subject to multi-axial stresses, the steepness of the load-life curve in the neighborhood of 50-100 N kg(-1) may overwhelm other material and mechanistic factors, thereby homogenizing the mass specific Fmax of grossly dissimilar animals and machines. Rockets scale with Group 1 motors but for different mechanistic reasons; they are free from fatigue constraints and their thrust is determined by mass flow rates that depend on cross sectional area of the exit nozzle. There is possibly a third scaling regime of Fmax for small motors (bacterial and spermatazoan flagella; a protozoan spring) where viscosity dominates over inertia. Data for force output of viscous regime motors are scarce, but the few data available suggest a gradually increasing scaling slope that converges with the Group 2 scaling relationship at a Reynolds number of about 10(2). The Group 1 and Group 2 scaling relationships intersect at a motor mass of 4400 kg, which restricts the force output and design of Group 2 motors greater than this mass. Above 4400 kg, all motors are limited by stress and have Fmax that scales as M0.67; this results in a gradual decline in mass specific Fmax at motor mass greater than 4400 kg. Because of declining mass specific Fmax, there is little or no potential for biological or engineered motors or rockets larger than those already in use.
منابع مشابه
A hierarchical analysis of the scaling of force and power production by dragonfly flight motors.
Maximum isometric force output by single muscles has long been known to be proportional to muscle mass(0.67), i.e to muscle cross-sectional area. However, locomotion often requires a different muscle contraction regime than that used under isometric conditions. Moreover, lever mechanisms generally affect the force outputs of muscle-limb linkages, which is one reason why the scaling of net force...
متن کاملMolecules, muscles, and machines: universal performance characteristics of motors.
Animal- and human-made motors vary widely in size and shape, are constructed of vastly different materials, use different mechanisms, and produce an enormous range of mass-specific power. Despite these differences, there is remarkable consistency in the maximum net force produced by broad classes of animal- and human-made motors. Motors that use force production to accomplish steady translation...
متن کاملScaling Laws in Robotics
Scaling laws are pervasive in biological systems, found in a large number of life processes, and across 27 orders of magnitude. Recent findings show both biological and engineered motors adhering to two fundamental regimes for the mass scaling of maximum force output. This scaling law is of particular interest for the robotics field as it can affect the design stage of a robot. In this study we...
متن کاملATRIAS - a human size compliant bipedal robot walks efficiently
Robot Hardware The bipedal robot ATRIAS has been developed for efficient and versatile locomotion. Its design was inspired by the spring-mass model, which has been proposed as a template for hopping, running and walking [1, 2]. The 60kg robot walks on two legs of 0.9m maximum length which are driven by two motors each, sharing the load of extending and rotating the leg. A carbon-fiber leaf spri...
متن کاملA Bayesian Nominal Regression Model with Random Effects for Analysing Tehran Labor Force Survey Data
Large survey data are often accompanied by sampling weights that reflect the inequality probabilities for selecting samples in complex sampling. Sampling weights act as an expansion factor that, by scaling the subjects, turns the sample into a representative of the community. The quasi-maximum likelihood method is one of the approaches for considering sampling weights in the frequentist framewo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of experimental biology
دوره 208 Pt 9 شماره
صفحات -
تاریخ انتشار 2005