Reflection mode photoacoustic measurement of speed of sound.
نویسندگان
چکیده
We present a method to determine the speed of sound in tissue using a double-ring photoacoustic sensor working in reflection mode. This method uses the cross-correlation between the laser-induced ultrasound waves detected by two concentric ring shaped sensors, while a priori information about the depth-position of the photoacoustic source is not required. We demonstrate the concept by estimating the speed of sound in water as a function of temperature. Comparison of the estimated speed with values reported in literature shows an average systematic error of 0.1% and a standard deviation of 0.1%. Furthermore, we demonstrate that the method can be applied to layered media. The method has application in the correction of photoacoustic and ultrasound images afflicted by local speed variations in tissue. Additionally, the concept shows promise in monitoring temperature changes which are reflected in speed of sound changes in tissue.
منابع مشابه
Reflection-mode multifocal optical-resolution photoacoustic microscopy.
Compared with single-focus optical-resolution photoacoustic microscopy (OR-PAM), multifocal OR-PAM utilizes both multifocal optical illumination and an ultrasonic array transducer, significantly increasing the imaging speed. A reflection-mode multifocal OR-PAM system based on a microlens array that provides multiple foci as well as an ultrasonic array transducer that receives the excited photoa...
متن کاملDeep reflection-mode photoacoustic imaging of biological tissue.
A reflection-mode photoacoustic (PA) imaging system was designed and built to image deep structures in biological tissues. We chose near-infrared laser pulses of 804-nm wavelength for PA excitation to achieve deep penetration. To minimize unwanted surface signals, we adopted dark-field ring-shaped illumination. This imaging system employing a 5-MHz spherically focused ultrasonic transducer prov...
متن کاملast 3 - D dark - field reflection - mode photoacoustic icroscopy in vivo with a 30 - MHz ultrasound inear array
ihong V. Wang ashington University in St. Louis ptical Imaging Laboratory epartment of Biomedical Engineering t. Louis, Missouri 63130 -mail: [email protected] Abstract. We present an in vivo dark-field reflection-mode photoacoustic microscopy system that performs cross-sectional B-scan imaging at 50 Hz with real-time beamforming and 3-D imaging consisting of 166 B-scan frames at 1 Hz wit...
متن کاملIn vivo dark-field reflection-mode photoacoustic microscopy.
Reflection-mode photoacoustic microscopy with dark-field laser pulse illumination and high-numerical-aperture ultrasonic detection is designed and implemented in noninvasively imaged blood vessels in the skin in vivo. Dark-field optical illumination minimizes the interference caused by strong photoacoustic signals from superficial structures. A high-numerical-aperture acoustic lens provides hig...
متن کاملReflection-mode submicron-resolution in vivo photoacoustic microscopy.
Submicron-resolution photoacoustic microscopy (PAM) currently exists only in transmission mode, due to the technical difficulties of combining high numerical-aperture (NA) optical illumination with high NA acoustic detection. The lateral resolution of reflection-mode PAM has not reached <2 μm in the visible light range. Here we develop the first reflection-mode submicron-resolution PAM system w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 15 6 شماره
صفحات -
تاریخ انتشار 2007