The gas proportional scintillation counter / microstrip gas chamber hybrid detector
نویسنده
چکیده
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedback due to the additional scintillation produced in the electron avalanche process at the MSP anodes, in the absence of quenching. A low-photoelectron collection efficiency is achieved in the gas atmosphere, resulting in a scintillation conversion efficiency that is about a factor of 5 lower than that achieved with PMT-based GPSCs. However, energy resolutions of 11% for 5.9 keV X-rays are achieved with this detector. r 2003 Elsevier Science B.V. All rights reserved. PACS: 07.85.Nc; 29.40.Cs; 29.40.Mc; 85.60.Ha
منابع مشابه
High-pressure operation of a xenon-GPSC/MSGC hybrid detector for hard X-ray spectrometry
The performance of a high-pressure xenon gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector has been investigated for filling pressures from 1 up to 10 bar, for 22-, 30and 60-keV photons. GPSC/MSGC hybrid detectors are based on a xenon-GPSC instrumented with a CsI-coated microstrip plate photosensor placed directly within the xenon envelope, as a substitut...
متن کاملشبیه سازی یک آشکارساز تناسبی میکرو نواری برای آشکارسازی گاز رادن و دختران با کد مونت کارلو (MCNPX)
Many detection methods have been applied to detect radon gas. Due to the low noise and high resolution of gas detectors compared to semiconductor detectors or scintillation detectors, using them to detect alpha radiation is very considerable. Microstrip proportional detector is also included in this group and it has not been used for the detection of radon. In this article, response of the micr...
متن کاملStaff exposure rate in Mahallat hot spring region
Background: High level radiation areas have been recognized on various parts of the earth. Mahallat hot spring region is one of these areas. Study of exposure in these areas can be helpful in investigating the effects of ionizing radiation. Internal and external exposure to the staff was studied. Materials and Methods: Used materials and instruments include: RSS-112 ionizing chamber fo...
متن کاملLow-background Experiments with High Pressure Gas Scintillation Proportional Detector
A scintillation proportional counter with wavelength shifting fiber readout filled with Xe or Kr under a pressure of up to 20 atm is proposed for the low–background experiments on search for dark matter of the Universe and 2K–decay of Kr.
متن کاملAn5 Radiation Detectors and Dosimetry
Aims Studying this chapter should give you some appreciation of the variety of radiation detectors available and equip you with some practical knowledge about their characteristics and uses. This chapter also contains practical knowledge about the description and measurement of the effects of radiation on humans. You should learn how the problem of measuring doses is currently handled in terms ...
متن کامل