An Image Guided Navigation System for Accurate Alignment in Total Hip Replacement Surgery
نویسندگان
چکیده
Dislocation following total hip replacement surgery (THR) remains a significant clinical problem. Malposition of the acetabular component increases the occurrence of impingement, reduces the " safe " range of motion and increases the risk of dislocation. Not fully understanding the interaction between pelvic orientation and final acetabular cup alignment may be one of the main contributing factors in the continued significant incidence of dislocations following total hip replacement. There has been little clinical research to examine the effects of patient positioning and pelvic motion on the alignment of the acetabular implant during total hip replacement surgery. Until now, no tools were capable of accurately measuring these variables during the actual procedure. As part of a broader program in medical robotics and computer assisted surgery, we have developed several enabling technologies that provide surgeons with a new class of image guided measurement tools and assist devices. These surgical navigation tools provide position and alignment information never before available intraoperatively. Our Hip Navigation system (HipNav) continuously and precisely measures and tracks pelvic location and relative implant alignment. HipNav technology is used to gauge current clinical practice and provide intraoperative feedback to surgeons in order to improve the precision and accuracy of acetabular alignment during THR. These tools were successfully introduced into the clinical practice of surgery with results showing that: a) there exist unpredictable and large variations of the initial position of patients' pelvii on the OR table as well as significant pelvic movement during surgery and during intraoperative range of motion testing; b) current mechanical acetabular alignment guides do not account for these variations, and result in variable and in some cases unacceptable acetabular alignment; and c) press fitting oversized acetabular components influences the final cup orientation.
منابع مشابه
[Our experience with an image guided navigation system for accurate alignment in total hip replacement by minimally invasive posterolateral surgery].
PURPOSE OF THE STUDY The aim of the study was to compare a radiographic position of the acetabular component with a position guided by the navigation system in final acetabular cup alignment. MATERIAL Between May and October 2005, 15 patients underwent implantation of a cementless acetabular component from the posterolateral minimally invasive approach with the use of kinematic navigation. ...
متن کاملCombined anteversion of the total hip arthroplasty implanted with image-free cup navigation and without stem navigation
In total hip arthroplasty (THA), combined anteversion (CA), the sum of cup anteversion (AV) and stem antetorsion (AT) are used as parameters to assess the appropriateness of overall prosthetic alignment. In this study, we evaluated the CA value based on the post-operative computed tomography (CT) measurements in our patient population who underwent THA using the OrthoPilot™ image-free navigatio...
متن کاملAccuracy of a computer-assisted navigation system for total knee replacement.
The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the...
متن کاملValidation of a CT-free navigation system for the measurement of native acetabular alignment
Computer assisted surgery is becoming more frequently used in medical world. OrthoPilotTM Hip Suite CT-free navigation system (BBraun Aesculap) is one such computer assisted navigation system used for total hip replacement surgery. The validity of OrthoPilot system remains to be determined independent of the manufacturer. The main aims of this study were to investigate the accuracy of OrthoPilo...
متن کاملIntellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty
Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term co...