An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations
نویسندگان
چکیده
In recent years, noninvasive thermal treatment by using high-intensity focused ultrasound (HIFU) has high potential in tumor treatment. The goal of this research is to develop an ultrasound imaging-guided robotic HIFU ablation system for tumor treatment. The system integrates the technologies of ultrasound image-assisted guidance, robotic positioning control, and HIFU treatment planning. With the assistance of ultrasound image guidance technology, the tumor size and location can be determined from ultrasound images as well as the robotic arm can be controlled to position the HIFU transducer to focus on the target tumor. After the development of the system, several experiments were conducted to measure the positioning accuracy of this system. The results show that the average positioning error is 1.01 mm with a standard deviation 0.34, and HIFU ablation accuracy is 1.32 mm with a standard deviation 0.58, which means this system is confirmed with its possibility and accuracy.
منابع مشابه
Preclinical ultrasound image-guided high intensity focused ultrasound robot system for breast cancer therapy
Background/introduction Ultrasound imaging provides real-time feedback for highly accurate positioning and dosing control. In addition, spatial restriction of high-intensity focused ultrasound (HIFU) transducer position in the ultrasound image-guided system is less than that in the case of MRI-guided system. Therefore, wider beam approaching path can be used in the ultrasound image-guided syste...
متن کامل3D MR neurography targeted peripheral nerve ablation with MR-guided high intensity focused ultrasound (MR-HIFU): initial results of a feasibility study in a swine model
Background/introduction MR-guided HIFU is an effective treatment for metastatic bone pain through periosteal nerve ablation,[1] and is being investigated for treating back pain through facet joint denervation.[2] For peripheral neuropathy, ultrasound-guided HIFU has been investigated preclinically as a means of achieving either an irreversible conduction block to treat severe spasticity [3], or...
متن کاملFUSBOTs: Image-guided Robotic Systems for FUS (Focused Ultrasound Surgery)
Minimally invasive and non-invasive surgical techniques remained a prime research focus in bio-medical arena in the past over two decades due to their numerous advantages over conventional surgery methods. Remote ablation of deep-seated abnormalities by various modalities such as the use of focused high intensity ultrasound can provide completely non-invasive procedures if the energy in the bea...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملSonalleve MR-HIFU with DISC Philips MR-guided High Intensity Focused Ultrasound with Direct Skin Cooling
High Intensity Focused Ultrasound guided by Magnetic Resonance Imaging (also known as MR-guided HIFU, MRgHIFU, or MRgFUS) is a therapy technique which uses focused ultrasound waves to heat and coagulate tissue deep inside the body without damaging intervening tissue and offers an novel, non-invasive treatment option for solid tumors. The Philips Sonalleve MR-HIFU system, initially released in 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017