Transmission line parameter identification using PMU measurements
نویسندگان
چکیده
Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMU’s). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully-transposed TL when measurement noise is absent; however these methods may generate erroneous parameters when the TL’s are not fully-transposed or when measurement noise is present. PMU field-measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short transmission lines. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TL’s that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short/long lines that are fully transposed or untransposed and have balanced/unbalance loads. Besides the positive/negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated.
منابع مشابه
Analysis of Synchronization and Accuracy of Synchrophasor Measurements by
i ABSTRACT In electric power systems, phasor measurement units (PMUs) are capable of providing synchronized voltage and current phasor measurements which are superior to conventional measurements collected by the supervisory control and data acquisition (SCADA) system in terms of resolution and accuracy. These measurements are known as synchrophasor measurements. Considerable research work has ...
متن کاملالگوریتم جامعی برای مکان یابی خطا در خطوط انتقال دو مداره و چند پایانه ای (بیش از سه پایانه) مبتنی بر داده های PMU
A new PMU-based fault detection/location algorithm for multi-terminal transmission lines is proposed in this paper, which works on the basis of synchronized voltage and current phasors received from PMUs installed in various terminals. The Clark transform (for transposed transmission lines), Eigen-values and eigenvectors theory (for un-transposed ones) are used to decouple 3-phase differential ...
متن کاملFault Location on Compensated Transmission Lines without Current Measurement
This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...
متن کاملAn Adaptive PMU Based Fault Detection/Location Technique for Transmission Lines—Part II: PMU Implementation and Performance Evaluation
Part I of this paper set sets forth theory and algorithms for adaptive fault detection/location technique, which is based on Phasor Measurement Unit (PMU). This paper is Part II of this paper set. A new timing device named “Global Synchronism Clock Generator, GSCG” including its hardware and software design is described in this paper. Experimental results show that the synchronized error of ris...
متن کاملIdentification of synchronous generator model with frequency control using unscented Kalman filter
In this paper, phasor measurement unit (PMU) data-based synchronous generator model identification is carried out using unscented Kalman filter (UKF). The identification not only gives the model of a synchronous generator’s swing dynamics, but also gives its turbine-governor model along with the primary and secondary frequency control block models. PMU measurements of active power and voltage m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1706.05917 شماره
صفحات -
تاریخ انتشار 2010