Detection of low-volume blood loss: compensatory reserve versus traditional vital signs.
نویسندگان
چکیده
BACKGROUND Humans are able to compensate for low-volume blood loss with minimal change in traditional vital signs. We hypothesized that a novel algorithm, which analyzes photoplethysmogram (PPG) wave forms to continuously estimate compensatory reserve would provide greater sensitivity and specificity to detect low-volume blood loss compared with traditional vital signs. The compensatory reserve index (CRI) is a measure of the reserve remaining to compensate for reduced central blood volume, where a CRI of 1 represents supine normovolemia and 0 represents the circulating blood volume at which hemodynamic decompensation occurs; values between 1 and 0 indicate the proportion of reserve remaining. METHODS Subjects underwent voluntary donation of 1 U (approximately 450 mL) of blood. Demographic and continuous noninvasive vital sign wave form data were collected, including PPG, heart rate, systolic blood pressure, cardiac output, and stroke volume. PPG wave forms were later processed by the algorithm to estimate CRI values. RESULTS Data were collected from 244 healthy subjects (79 males and 165 females), with a mean (SD) age of 40.1 (14.2) years and mean (SD) body mass index of 25.6 (4.7). After blood donation, CRI significantly decreased in 92% (α = 0.05; 95% confidence interval [CI], 88-95%) of the subjects. With the use of a threshold decrease in CRI of 0.05 or greater for the detection of 1 U of blood loss, the receiver operating characteristic area under the curve was 0.90, with a sensitivity of 0.84 and specificity of 0.86. In comparison, systolic blood pressure (52%; 95% CI, 45-59%), heart rate (65%; 95% CI, 58-72%), cardiac output (47%; 95% CI, 40-54%), and stroke volume (74%; 95% CI, 67-80%) changed in fewer subjects, had significantly lower receiver operating characteristic area under the curve values, and significantly lower specificities for detecting the same volume of blood loss. CONCLUSION Consistent with our hypothesis, CRI detected low-volume blood loss with significantly greater specificity than other traditional physiologic measures. These findings warrant further evaluation of the CRI algorithm in actual trauma settings. LEVEL OF EVIDENCE Diagnostic study, level II.
منابع مشابه
State-of-the-art monitoring in treatment of dengue shock syndrome: a case series
BACKGROUND Early recognition and treatment of circulatory volume loss is essential in the clinical management of dengue viral infection. We hypothesized that a novel computational algorithm, originally developed for noninvasive monitoring of blood loss in combat casualties, could: (1) indicate the central volume status of children with dengue during the early stages of "shock"; and (2) track fl...
متن کاملRunning on empty? The compensatory reserve index.
BACKGROUND Hemorrhage is a leading cause of traumatic death. We hypothesized that state-of-the-art feature extraction and machine learning techniques could be used to discover, detect, and continuously trend beat-to-beat changes in arterial pulse waveforms associated with the progression to hemodynamic decompensation. METHODS We exposed 184 healthy humans to progressive central hypovolemia us...
متن کاملEstimation of individual-specific progression to impending cardiovascular instability using arterial waveforms.
Trauma patients with "compensated" internal hemorrhage may not be identified with standard medical monitors until signs of shock appear, at which point it may be difficult or too late to pursue life-saving interventions. We tested the hypothesis that a novel machine-learning model called the compensatory reserve index (CRI) could differentiate tolerance to acute volume loss of individuals well ...
متن کاملPostpartum hemorrhage--update on problems of definitions and diagnosis.
Maternal mortality due to postpartum hemorrhage (PPH) continues to be one of the most important causes of maternal death worldwide. PPH is a significantly underestimated obstetric problem, primarily because a lack of definition and diagnosis. The 'traditional' definition of primary PPH based on quantification of blood loss has several limitations. Notoriously, blood loss is not measured or is s...
متن کاملPromoting early diagnosis of hemodynamic instability during simulated hemorrhage with the use of a real-time decision-assist algorithm.
BACKGROUND This study aimed to test the hypothesis that the addition of a real-time decision-assist machine learning algorithm by emergency medical system personnel could shorten the time needed to identify an unstable patient during a hemorrhage profile as compared with vital sign information alone. METHODS Fifty emergency medical team-paramedics from a large, urban fire department participa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of trauma and acute care surgery
دوره 77 6 شماره
صفحات -
تاریخ انتشار 2014