Pneumonia due to liquid paraffin: with chemical analysis.

نویسنده

  • C W Elston
چکیده

The first description of oil aspiration pneumonia in man was by Laughlen in 1925. He described 4 cases diagnosed at necropsy: 3 of the patients were infants and 1 was an adult. In 2 cases the administration of liquid paraffin by mouth was incriminated and in the other 2 oily nasal drops had been used. Pinkerton (1927) described 6 cases diagnosed at necropsy, 5 were infants and 1 was a 6-year-old boy. Of these, 5 had suffered from chronic ill-health; a history of mineral oil ingestion was obtained in 3 cases. Ikeda (1935) reported 7 cases collected from a series of 101 consecutive necropsies on children, and gave a lucid account of the pathological changes. In at least 2 liquid paraffin was thought to be the causative agent. Brimblecombe, Crome, and Tizard (1951) described a case of liquid paraffin pneumonia in a boy of 81 months, undiagnosed until necropsy. Bishop (1940) collected and reviewed 136, and Kaplan (1941) found references to 411 reported cases. More recently the American published reports were reviewed by Buechner and Strug (1956) and by Steinberg and Finby (1956). The majority of cases have not been diagnosed until necropsy. There are a few references to cases diagnosed in life, but most of them were adults with pulmonary oil granulomas. Thus Wagner, Adler, and Fuller (1955) presented 5 cases of liquid paraffin granulomas in adults, and Siddons (1958) reported 3 cases of oil granuloma initially diagnosed as carcinoma of the bronchus; in one of Siddon's cases it was established that liquid paraffin had been ingested. Cotton and Lloyd (1960) described another adult case, in which liquid paraffin pneumonia and nocardial infection complicated a long-standing case of achalasia of the cardia. In the majority of the recorded cases the diagnosis was made on purely histological grounds, and few authors have undertaken chemical extraction or attempted to identify the causative oil. In the 40 years since Laughlen's original report

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fire-eater's pneumonia after aspiration of liquid paraffin.

Fire-eater's pneumonia is a distinct type of chemical pneumonitis that results from aspiration of different types of hydrocarbons. This article describes a case of fire-eater's pneumonia due to accidental aspiration of liquid paraffin. The adolescent patient became febrile the day after the accident. The diagnosis of fire-eater's pneumonia was delayed because aspiration history was not divulged...

متن کامل

An unnecessary case of paraffin oil pneumonia.

A 64-year-old woman died after 12 years of progressive pulmonary disease which was initially diagnosed as sarcoidosis but later correctly identified as mineral oil pneumonia due to insufflation of paraffin instilled as nasal drops. In view of the potential damaging effect of liquid paraffin on the lungs, the current indications for its use must be strongly questioned.

متن کامل

A case of chronic paraffin pneumonitis.

Although the syndrome of an exogenous lipoid pneumonia due to aspirated liquid paraffin has been established for some four decades, it is evident from many of the published reports, mainly in the American literature, that the diag-nosis is still frequently being missed unless investigations are deliberately undertaken with this possibility in mind. Rewell (1947) published the -first probable ca...

متن کامل

Investigation with rheological behavior of liquid paraffin/Al2O3 nanofluid: Experimental approach

Liquid paraffin can be used as a coolant fluid in electronic and cutting devices due to its suitable capabilities such as electrical insulating, high heat capacity, chemical, and thermal stability, and high boiling point. In this study, the dynamic viscosity of paraffin containing the alumina nanoparticles has been examined experimentally. The nanofluids with different composition of alumina (0...

متن کامل

Experimental Investigation of the Alumina/Paraffin Thermal Conductivity Nanofluids with a New Correlated Equation on Effective Thermal Conductivity

Liquid paraffin as a coolant fluid can be  applied in electronic devices as a result to its suitable capabilities such as electrical insulating, high heat capacity, chemical and thermal stability, and high boiling point. However, the poor thermal conductivity of paraffin has been confined its thermal cooling application. Addition of high conductor nanoparticles to paraffin can fix this drawback...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 41 218  شماره 

صفحات  -

تاریخ انتشار 1966