Optimisation of sampling parameters for standardised exhaled breath sampling.

نویسندگان

  • Sophie Doran
  • Andrea Romano
  • George B Hanna
چکیده

The lack of standardisation of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole versus lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000 ml); and (iii) breath sample flow rate (400, 200, 100 and 50 ml min-1). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' reduces the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to elicit potential biomarkers of gastro-oesophageal cancer, the optimum parameters are 500 mls sample volume of whole breath with a flow rate of 200 ml min-1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive models of ethanol concentrations in simulated exhaled breath and exhaled breath condensate under varied sampling conditions

Breath monitoring is a non-invasive, safe, and repeatable approach to determining the respiratory, gastrointestinal, and general health status of humans and other mammals. Breath samples could be detected in two ways—directly sensing exhaled breath (EB) or chilling the EB to obtaining the exhaled breath condensate (EBC). Each has its advantages and disadvantages but they are both affected by di...

متن کامل

ساخت نمونه بردار کندانس هوای بازدمی جهت مطالعه بیومارکرهای بازدمی استرس اکسیداتیو

Background: The use of exhaled breath condensate (EBC) biomarkers to evaluate exposure and disease in recent years gained attention in toxicology and occupational medicine. However, use of standard sampling apparatus is missing element in this procedure. Methods: Initial design of sampler was selected based on the water condensation system. The effect of sampler length, sampling time and tempe...

متن کامل

Checking of gas sampling tube by direct measurement of exhaled breath.

EDITOR: We read with interest the article published by Gauthama and Morris [1] in which the authors reported the findings of a survey of UK anaesthetists for checking the capnograph before anaesthesia. The authors reported that majority of UK anaesthetists use exhaled breath to check the capnograph but the practice is not universal due to concerns of sterility. We wish to report a critical inci...

متن کامل

Standardization of the collection of exhaled breath condensate and exhaled breath aerosol using a feedback regulated sampling device.

Exhaled breath condensate (EBC) and associated exhaled breath aerosols (EBA) are valuable non-invasive biological media used for the quantification of biomarkers. EBC contains exhaled water vapor, soluble gas-phase (polar) organic compounds, ionic species, plus other species including semi- and non-volatile organic compounds, proteins, cell fragments, DNA, dissolved inorganic compounds, ions, a...

متن کامل

Off-line sampling of exhaled air for nitric oxide measurement in children: methodological aspects.

Measurement of nitric oxide in exhaled air is a noninvasive method to assess airway inflammation in asthma. This study was undertaken to establish the reference range of exhaled NO in healthy school-aged children and to determine the influence of ambient NO, noseclip and breath-holding on exhaled NO, using an off-line balloon sampling method. All children attending a primary school (age range 8...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of breath research

دوره   شماره 

صفحات  -

تاریخ انتشار 2017