Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment.

نویسندگان

  • C Caiati
  • N Zedda
  • C Montaldo
  • R Montisci
  • S Iliceto
چکیده

OBJECTIVES The purpose of this study is to evaluate the feasibility in detecting blood flow in the left anterior descending coronary artery (LAD) using transthoracic color Doppler (CD) imaging (in both second harmonic and fundamental mode) along with contrast enhancement and to verify if this new noninvasive method along with adenosine is safe, rapid and effective in assessing coronary flow reserve (CFR). BACKGROUND Feasibility of contrast-enhanced transthoracic Doppler recording (in both second harmonic and fundamental mode) of blood flow velocity in the LAD has not been assessed. Adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole and thus it can be more suitable for assessing CFR in conjunction with this method. METHODS Sixty-one patients with angiographically patent LAD underwent CD (both in fundamental and harmonic mode) as well as color-guided pulsed wave (PW) Doppler recording of blood flow velocity in the distal LAD before and after intravenous contrast injection. A second group of patients (n = 77), undergoing coronary angiography, was submitted to transthoracic contrast-enhanced PW Doppler recording of blood flow velocity in the LAD using harmonic CD as a guide, at rest and during adenosine-induced hyperemia. RESULTS Harmonic CD along with echo contrast consistently improved blood flow detection in the LAD; the success rate in detecting flow of optimal quality was 88% with this approach, whereas it was 11% and 16% with CD in fundamental mode, respectively, before and after contrast. Pulsed wave Doppler results paralleled those of harmonic CD (p < 0.001 contrast harmonic vs. fundamental). In the second group of patients coronary angiography revealed 0% to <40% stenosis in 24 patients (group I), > or =40% to < or =75% in 17 patients (group II) and >75% stenosis in 34 patients (group III). There was a significant difference in CFR among the three groups of patients; CFR for peak diastolic velocity was (mean +/- SD): 2.88+/-0.7 (group I), 2.09+/-0.5 (group II) and 1.51+/-0.5 cm/s (group II) (p < 0.05 group I vs. both group II and group III; p < 0.05 group II vs. group III). The whole examination took less than 10 min. CONCLUSIONS Contrast-enhanced second harmonic Doppler recording of blood velocity in the LAD is highly feasible and in combination with adenosine it is a rapid, safe and effective method for assessing CFR ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Routine elective cesarean section is not justified for women with mechanical heart valves.

1. Caiati C, Zedda N, Montaldo C, Montisci R, Iliceto S. Contrastenhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment. J Am Coll Cardiol 1999;34:122–30. 2. Sudhir K, MacGregor JS, Barbant SD, et al. Assessment of coronary conductance and resistance vessel reactivity in response to nitroglycerin, ergono...

متن کامل

New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler.

BACKGROUND We tested the hypothesis that blood flow velocity could be recorded in the left anterior descending coronary artery (LAD) during transthoracic echocardiography by use of second harmonic echo Doppler modality along with contrast enhancement (intravenous Levovist) at rest and after pharmacologically induced maximal vasodilation to assess coronary flow reserve (CFR) with a totally nonin...

متن کامل

New Methods Validation of a New Noninvasive Method (Contrast-Enhanced Transthoracic Second Harmonic Echo Doppler) for the Evaluation of Coronary Flow Reserve Comparison With Intracoronary Doppler Flow Wire

RESULTS As a result of the combined use of IV contrast and second harmonic Doppler technology, feasibility in assessing coronary flow reserve equaled 100%. The agreement between the two methods was high. In fact, in all but five patients the maximum difference between the two CFR measurements was 0.38. Overall, the prediction (95%) interval of individual differences was 20.69 to 10.72. Reproduc...

متن کامل

Assessment of coronary flow reserve by contrast-enhanced second harmonic echo Doppler.

Contrast-Enhanced Second Harmonic Echo Doppler To the Editor: With regard to the recent article by Caiati et al on the use of echo Doppler for the noninvasive determination of coronary flow reserve,1 several issues regarding this methodology should be clarified to ensure correct interpretation of the data. The authors used contrast-enhanced Doppler to determine blood flow velocity in coronary a...

متن کامل

Assessment of Coronary Flow Reserve by Contrast-Enhanced Second Harmonic

Contrast-Enhanced Second Harmonic Echo Doppler To the Editor: With regard to the recent article by Caiati et al on the use of echo Doppler for the noninvasive determination of coronary flow reserve,1 several issues regarding this methodology should be clarified to ensure correct interpretation of the data. The authors used contrast-enhanced Doppler to determine blood flow velocity in coronary a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 1999