Portable light transmission measuring system for preserved corneas

نویسندگان

  • Liliane Ventura
  • Gabriel Torres de Jesus
  • Gunter Camilo Dablas de Oliveira
  • Sidney JF Sousa
چکیده

BACKGROUND The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. METHODS The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400-700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. RESULTS Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. CONCLUSION By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physical and Biological Characterization of the Gamma-Irradiated Human Cornea.

PURPOSE To compare the physical and biological characteristics of commercial gamma-irradiated corneas with those of fresh human corneas and to determine suitability for transplantation. METHODS The physical properties of gamma-irradiated and fresh corneas were evaluated with respect to light transmittance, hydration (swelling ratio), elastic modulus (compressive modulus by the indentation met...

متن کامل

The Effect of Lyophilization on Light Transmission of Amniotic Membrane: A Comparison with Rabbit Cornea

Background & Aims: Amniotic membrane persists for a long time after ocular transplantation (as corneal substitute) and can affect light transmission (transparency). The aim of this study was to evaluate the transparency of amniotic membrane after freeze-drying (lyophilization) and to compare the results with transparency of rabbit cornea. Methods: Transparency of rabbits’ corneas and fresh and ...

متن کامل

The spectral transmission of non-salticid spider corneas.

Although many salticid spiders have been shown to have corneas that transmit ultraviolet (UV) light, whether the corneas of non-salticid spiders transmit UV has not been previously investigated. In this study, we determined the spectral corneal transmission properties of 38 species belonging to 13 non-salticid families. We used these data to estimate the T50 transmission cut-off value, the wave...

متن کامل

Design and construction of a portable unite for measuring body-fluid components

Introduction: In the laboratory, the time required to measure body-fluids components is usually one to two working days. The laboratory methods require sample preparation and instrument cleaning after the sample reading. In emergency scenarios, the physician does not have much time to make a clinical decision. To solve these challenges, a portable system for measuring the body fluids components...

متن کامل

Development and Validation of Sound Transmission Loss Measurement System for Measuring Muffler Performance

Muffler is a part of the vehicle exhaust system that absorb or reflect sound waves to reduce exhaust noise. One of the most important determinants of a muffler performance is the amount of attenuation that has on its input wave; this parameter is known as sound transmission loss. Four - mic standard test is one way to determine this parameter which is used in this paper. In this study, a test d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2005