Ultrahigh speed spectral / Fourier domain ophthalmic OCT imaging

نویسندگان

  • Fabrice Manns
  • Per G. Soderberg
  • Benjamin Potsaid
  • Iwona Gorczynska
  • Vivek J. Srinivasan
  • Yueli Chen
  • Jonathan Liu
  • James Jiang
  • Alex Cable
  • Jay S. Duker
  • James G. Fujimoto
چکیده

Ultrahigh speed spectral / Fourier domain optical coherence tomography (OCT) using a CMOS line scan camera with image acquisition rates of 70,000 312,500 axial scans per second is investigated. Several design configurations are presented to illustrate design trade-offs between acquisition speed, sensitivity, resolution and sensitivity roll-off performance. We demonstrate: extended imaging range and improved sensitivity roll-off at 70,000 axial scans per second with 4096 camera pixels, high speed and ultrahigh resolution imaging at 106,382 axial scans per second, and ultrahigh speed imaging at 250,000-312,500 axial scans per second. Each configuration is characterized through optical testing and the trade-offs demonstrated with in vivo imaging of the fovea and optic disk in the human retina. We show dense homogeneous 3D-OCT volumetric data sets that were acquired by raster scanning at 250,000 axial scans per second, which is an order of magnitude faster than most current generation spectral / Fourier OCT instruments. OCT fundus images constructed from the 3D-OCT data have no noticeable discontinuity of retinal features and show that there are minimal motion artifacts. Using an improved sensitivity roll-off configuration at 70,000 axial scans per second, long cross sectional scans are acquired at high resolution for imaging large areas of the retina, including the fovea and optic disk. Using an ultrahigh speed configuration at 250,000 axial scans per second, the fine porous structures of the lamina cribrosa can be seen from slices extracted from a dense 3D data set. Rapid repeated imaging of a small volume (4D-OCT) enables time resolved visualization of the capillary network surrounding the INL and may show individual red blood cells. This capability could create the possibility for alternative techniques for quantifying capillary blood flow, which cannot be measured with Doppler OCT methods because of the capillary’s perpendicular orientation to the optical beam. The results of this study suggest that high speed CMOS cameras can achieve a significant improvement in performance for ophthalmic imaging. This promises to have a powerful impact in clinical applications by improving early diagnosis, reproducibility of quantitative measurements and enabling more sensitive assessment of disease progression or response to therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm Citation

The performance and imaging characteristics of ultrahigh speed ophthalmic optical coherence tomography (OCT) are investigated. In vivo imaging results are obtained at 850nm and 1050nm using different configurations of spectral and swept source / Fourier domain OCT. A spectral / Fourier domain instrument using a high speed CMOS linescan camera with SLD light source centered at 850nm achieves spe...

متن کامل

Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.

We demonstrate ultrahigh speed swept source/Fourier domain ophthalmic OCT imaging using a short cavity swept laser at 100,000 - 400,000 axial scan rates. Several design configurations illustrate tradeoffs in imaging speed, sensitivity, axial resolution, and imaging depth. Variable rate A/D optical clocking is used to acquire linear-in-k OCT fringe data at 100 kHz axial scan rate with 5.3 um axi...

متن کامل

Blood flow measurement and slow flow detection in retinal vessels with Joint Spectral and Time domain method in ultrahigh speed OCT

We present an application of the Joint Spectral and Time domain OCT (STdOCT) method for detection of wide range of flows in the retinal vessels. We utilized spectral/Fourier domain OCT (SOCT) technique for development of scan protocols for Doppler signal analysis. We performed retinal imaging in normal eyes using ultrahigh speed (200 000 axial scans/s) SOCT instrument with a CMOS camera. Variou...

متن کامل

Ultrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head.

PURPOSE To demonstrate ultrahigh-speed optical coherence tomography (OCT) imaging of the retina and optic nerve head at 249,000 axial scans per second and a wavelength of 1060 nm. To investigate methods for visualization of the retina, choroid, and optic nerve using high-density sampling enabled by improved imaging speed. METHODS A swept-source OCT retinal imaging system operating at a speed ...

متن کامل

Ultrahigh speed optical coherence tomography : New developments for ophthalmic imaging

Optical coherence tomography (OCT) is an imaging technique providing depthresolved, cross-sectional imaging of biological tissues with micrometer scale resolution. Recent advances in sensitivity and imaging speed have enabled the acquisition of three dimensional (3D) data sets. In ophthalmology, OCT has become an indispensible imaging tool for diagnosis of disease and monitoring therapy. While ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009