Susceptibility testing of anaerobic bacteria: evaluation of the redesigned (Version 96) bioMérieux ATB ANA device.
نویسندگان
چکیده
We compared the susceptibility results for 200 clinical anaerobes with nine antibiotics obtained by using a new ATB ANA (bioMérieux) device against those obtained by the National Committee for Clinical Laboratory Standards (NCCLS) standard agar dilution method. For better evaluation of the device, we added some resistant Bacteroides fragilis group strains from our own collection: 3, 6, and 12 strains that were resistant to imipenem, ticarcillin plus clavulanic acid, and co-amoxiclav, respectively, and 2 other strains with decreased susceptibility to metronidazole. For some strains that did not grow on ATB S medium, tests were performed by using West-Wilkins medium supplemented with 1.5% agar. The new ATB ANA device made clinical categorization of the investigated strains possible, according to French (Committee of the Antibiogram of the French Society of Microbiology) or U.S. (NCCLS) breakpoints, with the following respective results: category agreement, 94.3 and 94.9%; minor errors, 4.8 and 3.8%; major errors, 0.4 and 0.8%; and very major errors 4.6 and 4.2%. The ATB ANA device was able to detect low-level metronidazole-resistant B. fragilis strains according to the French breakpoints but not the NCCLS ones. For B. fragilis and beta-lactamase-positive Prevotella strains, the clustering effect of amoxicillin MICs around the French breakpoints led to more frequent minor errors. ATB ANA is a very convenient method to determine the antibiotic susceptibilities of anaerobes. Results obtained by ATB ANA correlated well with those obtained by the reference method.
منابع مشابه
Antimicrobial Susceptibility of Clinical Isolates of Bacteroides fragilis Group Organisms Recovered from 2009 to 2012 in a Korean Hospital
BACKGROUND Periodic monitoring of antimicrobial resistance trends of clinically important anaerobic bacteria such as Bacteroides fragilis group organisms is required. We determined the antimicrobial susceptibilities of clinical isolates of B. fragilis group organisms recovered from 2009 to 2012 in a tertiary-care hospital in Korea. METHODS A total of 180 nonduplicate clinical isolates of B. f...
متن کاملTrends in antimicrobial susceptibility among anaerobes in Gran Canaria: Analysis of 15-years data.
In the last years an increase in the anaerobes resistance has een worldwide reported1,2; however, most studies only refer to acteroides fragilis group and antibiotic susceptibility data of other enus are limited. Although reasons that may lead to failure of herapy include lack of surgical drainage or poor source control, as ell as patient’s comorbidities and poor penetration and low levls of an...
متن کاملThe Widely Used ATB FUNGUS 3 Automated Readings in China and Its Misleading High MICs of Candida spp. to Azoles: Challenges for Developing Countries' Clinical Microbiology Labs
The rapid development in the clinical microbiology diagnostic assays presents more challenges for developing countries than for the developed world, especially in the area of test validation before the introduction of new tests. Here we report on the misleading high MICs of Candida spp. to azoles using the ATB FUNGUS 3 (bioMérieux, La Balme-les Grottes, France) with automated readings in China ...
متن کاملComparative evaluation of ATB Fungus 2 and Sensititre YeastOne panels for testing in vitro Candida antifungal susceptibility.
ATB Fungus 2 and SensititreYeastOne are commercial methods for antifungal susceptibility testing of yeasts. The agreement between these two methods was assessed with a total of 133 Candida strains (60 Candida albicans, 18 Candida dubliniensis, 29 Candida glabrata, and 26 Candida krusei). MIC endpoints were established after 24 h of incubation at 36-/+1 degrees C by each method. Intra-laboratory...
متن کاملA survey of the identification and susceptibility testing of anaerobes in diagnostic microbiology laboratories in Scotland, UK.
Sir, The methodology and reproducibility of the susceptibility testing of anaerobes in routine diagnostic laboratories has frequently been identified as problematic. However, reports of reduced susceptibility of various anaerobes to a range of antimicrobial agents underlines the importance for some semblance of a surveillance programme to detect emerging patterns of resistance that may impact o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 37 6 شماره
صفحات -
تاریخ انتشار 1999