Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves

نویسندگان

  • Ovandir Bazan
  • Jayme Pinto Ortiz
  • Francisco Ubaldo Vieira Junior
  • Reinaldo Wilson Vieira
  • Nilson Antunes
  • Fabio Bittencourt Dutra Tabacow
  • Eduardo Tavares Costa
  • Orlando Petrucci Junior
چکیده

INTRODUCTION In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. OBJECTIVE To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. METHODS To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min.) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. RESULTS It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. CONCLUSIONS Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Velocimetria laser de escoamento permanente através de duas próteses cardíacas de duplo folheto

Introduction: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mech...

متن کامل

Design of a fourth generation prosthetic heart valve: tri-leaflet valve

ASBTRACT Introduction: The interest in developing a prosthetic heart tri-laeflet valve is based on the durability of mechanical prosthesis; the good hemodynamic performance of bio-prosthesis due to the central flow, its perfect closure, the negligible thrombogenic index, and the negligible perception of its presence by the user. Objectives: Develop a mathematical model of a fourth generation pr...

متن کامل

Comparison of the occurrence of thromboembolic and bleeding complications in patients with mechanical heart valve prosthesis with one and two leaflets in the mitral position

INTRODUCTION Patients with mechanical heart valve prostheses must continuously be treated with oral anticoagulants to prevent thromboembolic events related to prosthetesis. These patients should be continually evaluated for the control of oral anticoagulation. OBJECTIVE To compare the occurrence of thromboembolic and hemorragic complications in patients with mechanical heart valve prosthesis ...

متن کامل

The effect of varying degrees of stenosis on the characteristics of turbulent pulsatile flow through heart valves.

Many problems and complications associated with heart valves are related to the dynamic behavior of the valve and the resultant unsteady flow patterns. An accurate depiction of the spatial and temporal velocity and rms distributions imparts better understanding of flow related valve complications, and may be used as a guideline in valve design. While the generalized correlation between increase...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2013