Comparative Analysis on Control Methods of Shunt Active Power Filter for Harmonics Mitigation
نویسندگان
چکیده
This paper presents an overview of different control methods which are applied on Shunt Active Power Filter to achieve harmonics reduction and power factor improvement. In recent decades, the world has seen an expansion in the use of non-linear loads. These loads draw a non-sinusoidal current from the source and distribute them throughout the system. As a result the power quality degrades. Therefore, Active Power Filter and its control have been proposed which provides excellent harmonic compensation and power quality improvement.
منابع مشابه
Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملComparative Analysis between PI and Fuzzy Controllers for Dc Voltage Control of Unbalanced 4 Wire Shunt Active Power Filter
This research proposes a shunt active power filter (SAPF) for harmonics mitigation in order to improve power quality of the electrical network. The reference harmonic current extraction technique used was based on DQ0 power theory under unbalanced non-linear loads conditions for four wire-installed systems. The DC-link voltage plays an important role in SAPF design to guarantee both steady high...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملComparative Analysis of Filters to Mitigate Harmonics for Power Quality Enhancement
Due to the advancement in power electronic equipments and increase in the usage of non-linear loads in power distribution system, the undesirable harmonics are introduced that degrade the quality of power. Presence of harmonics are always detrimental to power system that results in irreversible failure of electrical components, sometimes apart from frequently known heating issues in it. There a...
متن کاملFuzzy Based Current Harmonic Suppression and Reactive Power Compensation in a Grid Connected PV System Using Shunt Active Filter
The photovoltaic (PV) system exhibits a nonlinear current-voltage (I-V) characteristic that its maximum power point (MPP) varies with solar insolation and temperature. In this paper, a maximum power point tracking (MPPT) method using fuzzy logic control (FLC) is presented. This method is based on the concept of perturbation and observation (P & O) algorithm to track the MPP. The two stage grid ...
متن کامل