Retrospective rigid motion correction of undersampled MRI data

نویسندگان

  • Alexander Loktyushin
  • Maryna Babayeva
  • Daniel Gallichan
  • Gunnar Krueger
  • Klaus Scheffler
  • Tobias Kober
چکیده

motion correction pipeline. 2334 Retrospective rigid motion correction of undersampled MRI data Alexander Loktyushin, Maryna Babayeva, Daniel Gallichan, Gunnar Krueger, Klaus Scheffler, and Tobias Kober Empirical Inference, Max Planck Institute for Intelligent Systems, Tübingen, Germany, Siemens ACIT CHUV Radiology, Siemens Healthcare IM BM PI, & Department of Radiology, University Hospital (CHUV), Lausanne, Switzerland, LTS5, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland, CIBM, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland, High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany, Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A frame work for non-rigid motion corrected compressed sensing for highly accelerated MRI

Introduction: Compressed Sensing (CS) has been demonstrated to reconstruct sparse MR images of adequate quality from highly undersampled data [1], resulting in reduced scan times. In MRI, extensive motion during the acquisition (e.g. respiratory motion in cardiac scans) can cause inconsistencies in the k-space data, introducing blurring and ghosting like motion artefacts in the reconstructed im...

متن کامل

Combined Prospective Rigid-Body Motion Correction with Retrospective Non-Rigid Distortion Correction for EPI

Introduction: Prospective real-time motion correction, where the scan-plane orientation is dynamically updated to track with the subject's head during an MRI scan, is becoming increasingly popular (1-7). While these methods focus on compensating for bulk rigid-body motion, a secondary effect of head motion is non-rigid-body image distortion caused by changes in the effective shim within the bra...

متن کامل

Motion corrected compressed sensing for free-breathing dynamic cardiac MRI.

Compressed sensing (CS) has been demonstrated to accelerate MRI acquisitions by reconstructing sparse images of good quality from highly undersampled data. Motion during MR scans can cause inconsistencies in k-space data, resulting in strong motion artifacts in the reconstructed images. For CS to be useful in these applications, motion correction techniques need to be combined with the undersam...

متن کامل

Motion Estimated-Compensated Reconstruction with Preserved-Features in Free-Breathing Cardiac MRI

To develop an efficient motion-compensated reconstruction technique for free-breathing cardiac magnetic resonance imaging (MRI) that allows high-quality images to be reconstructed from multiple undersampled single-shot acquisitions. The proposed method is a joint image reconstruction and motion correction meth-od consisting of several steps, including a non-rigid motion extraction and a motion-...

متن کامل

Comparison of Non-rigid Motion Compensated Reconstructions for 3d Abdominal Mri

INTRODUCTION: Respiratory motion is a major challenge for 3D abdominal MRI. Respiratory navigator gating is commonly used to compensate for motion, but leads to low scan efficiency. Recently, a free-breathing motion compensated technique was proposed that estimates 3D non-rigid motion from undersampled reconstructed images. This technique compensates motion by warping the undersampled images to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014