A new thoron reference ((220)Rn) in air measurement system is developed at the LNE-LNHB with the collaboration of the IRSN. This measurement system is based on a reference volume with an alpha detector which is able to directly measure thoron and its decay products at atmospheric pressure. In order to improve the spectrum quality of the thoron progenies, we have applied an electric field to catch the decay products on the detector surface. The developed system is a portative device which can be used to measure reference thoron atmosphere such as the BACCARA chamber at IRSN (Picolo et al., 1999). As this system also allows the measurement of radon ((222)Rn) in air, it was validated using the radon primary standards made at the LNE-LNHB. This thoron measurement system will be used, at IRSN, as a reference instrument in order to calibrate the thoron activity concentration in the BACCARA facility.
منابع مشابه
Measurements of Radon and Thoron Decay Products in Air. an Application of Lsc and Tld Methods
Liquid Scintillation Counting (LSC) is a measuring technique, broadly applied in environmental monitoring of different radionuclides. One of the possible applications of LSC is the measurement of radon and thoron progeny. There are certain advantages of this method, especially high counting efficiency for alpha and beta particles emitted by radon and thoron progeny. This advantage has been poin...
متن کاملEstimation of thoron concentration using scintillation cell.
Two counting techniques are proposed in this paper to estimate thoron ((220)Rn) concentration using a Lucas scintillation cell. The alpha activity build-up inside the cell is calculated theoretically by using Bateman equations. The first method is having a minimum detection limit of 325 Bq m(-3) and can be used for thoron measurement in thorium-processing plants. In the second method, thoron co...
متن کاملMEASUREMENT OF ""Rn (THORON) USING ELECTRET ION CHAMBERS
Recently there has been an increased interest in the measurement of airborne ""Rn (thoron). Such measurements are particularly targeted in areas rich in thorium, and in facilities processing thorium compounds and associated radioactive wastes. Standard electret ion chambers @-PERMSR)* designed for making indoor and outdoor "^Rn (radon) measurement have very little response to "¡R (thoron). How...
متن کاملA Simulation Study of Lognormal Measurement Error Effect −Discrimination Problem of Radon and Thoron−
Several case-control studies have indicated an increased risk of lung cancer linked to indoor radon exposure. For a precise evaluation of radon-related lung cancer risk, however, contribution of thoron should be considered. There are a lot of studies in which passive type radon detectors are used without thoron discrimination techniques. Therefore, these passive type radon detectors may be stro...
متن کاملMitigation of radon and thoron decay products by filtration.
Inhalation of indoor radon ((222)Rn) and thoron ((220)Rn) decay products is the most important source of exposure to ionizing radiation for the human respiratory tract. Decreasing ventilation rates due to energy saving reasons in new buildings suggest additional active mitigation techniques to reduce the exposure in homes with high radon and thoron concentrations but poor ventilation. Filtratio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 109 شماره
صفحات -
تاریخ انتشار 2016