Development of Naphthalene PLIF for Visualizing Ablation Products from a Space Capsule Heat Shield

نویسنده

  • C. S. Combs
چکیده

The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield. To better design this heat shield and others that will undergo planetary entry, an improved understanding of the ablation process would be beneficial. Here, a technique developed at The University of Texas at Austin that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to enable visualization of the ablation products in a hypersonic flow is applied. Although high-temperature ablation is difficult and expensive to recreate in a laboratory environment, low-temperature sublimation creates a limited physics problem that can be used to explore ablation-product transport in a hypersonic flow-field. In the current work, a subscale capsule reentry vehicle model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel. The PLIF technique provides images of the spatial distribution of sublimated naphthalene in the heat-shield boundary layer, separated shear layer, and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. PLIF images have shown high concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure. It was shown that, in general, the capsule shear layer appears to be more unsteady at lower angels of attack. The PLIF images demonstrated that during a wind tunnel run, as the model heated up, the rate of naphthalene ablation increased, since the PLIF signal increased steadily over the course of a run. Additionally, the shear layer became increasingly unsteady over the course of a wind tunnel run, likely because of increased surface roughness but also possibly because of the increased blowing. Regions with a relatively low concentration of naphthalene were also identified in the capsule backshell recirculation region and are most likely the result of cross-flow-induced vortices on the capsule afterbody.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NUMERICAL MODELING OF CHARRING MATERIAL ABLATION WITH CONSIDERING CHEMICAL REACTION, MASS TRANSFER AND SURFACE HEAT TRANSFER EFFECTS

Presently there is a little information that relates to heat shield systems.  Also this information is not certain in so many cases.  The main reason is that accurate calculations for measuring the sacrificing rate of various materials have not been obtained yet.  Additionally, the real scale test has two disadvantages: high cost and low flexibility, and for each case we must perform a new test...

متن کامل

Experimental and finite element vibrational analysis of exhaust manifold heat shield

Most of internal combustion engines have one or two heat shields that have been installed on the exhaust manifold to avoid the heat transfer to upper parts of the engine such as the valve cover. In some engines, this part fails due to the fracture and causes engine noise and other failures in the engine. In this paper, the failure of a heat shield due to vibrational loads of the engine has been...

متن کامل

Simulation of Temperature Distribution in Hot Strip over Transfer Table

Transfer table is an essential stage between roughing and finishing rolling stands in a hot-strip rolling mill. High temperature and long time that strip is exposed to air at this stage cause a considerable heat loss that accounts for uneven temperature distribution, non-uniform surfaces, reduced product quality and increased production costs. Using thermal shields on the transfer table is cons...

متن کامل

A magnetohydrodynamic simulation of pellet ablation in the electrostatic approximation

A magnetohydrodynamic numerical model for hydrogenic pellet ablation in the electrostatic approximation has been developed based on the method of front tracking. The main features of the model are the explicit tracking of interfaces that separate the solid pellet from the ablated gas and the cold, dense and weakly ionized ablation cloud from the highly conducting fusion plasma, a surface ablati...

متن کامل

Wireless Capsule Endoscopy as a Diagnostic Technique in Disorders of the Esophagus, Small Bowel and Colon

©2013 Blue Cross and Blue Shield of Louisiana An independent licensee of the Blue Cross and Blue Shield Association No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise, without permission from Blue Cross and Blue Shield of Louisiana. Page 1 of 13 Applies to all products admin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014