Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters.
نویسندگان
چکیده
OBJECTIVES We sought to determine the clinical and echocardiographic parameters that differentiate thrombus from pannus formation as the etiology of obstructed mechanical prosthetic valves. BACKGROUND Distinction of thrombus from pannus on obstructed prosthetic valves is essential because thrombolytic therapy has emerged as an alternative to reoperation. METHODS We analyzed clinical, transthoracic and transesophageal echocardiography (TEE) data in 23 patients presenting with 24 obstructed prosthetic valves and compared the findings to pathology at surgery. RESULTS Fourteen valves had thrombus and 10 had pannus formation. Patients with thrombus had a shorter duration from time of valve insertion to malfunction, shorter duration of symptoms, but similar New York Heart Association functional class at the time of operation. Patients with thrombus had a lower rate of adequate anticoagulation (21% vs. 89%; p=0.0028). Pannus formation was more common in the aortic position (70% vs. 21%; p=0.035). Abnormal prosthetic valve motion was detected by TEE in all cases with thrombus formation but in 60% with pannus (p=0.0198). Thrombi were larger than pannuses (total length 2.8+/-2.47 cm vs. 1.17+/-0.43 cm; p=0.038). This was mostly due to extension of thrombi into the left atrium in prosthetic mitral valves. Thrombi appeared as a soft mass on the valve in 92% of cases, whereas 29% of pannuses had a soft echo density (p= 0.007). Ultrasound video intensity ratio, derived as the videointensity of the mass to that of the prosthetic valve, was lower in the thrombus group (0.46+/-0.14 vs. 0.71+/-0.17, p=0.006). A videointensity ratio of <0.70 had a positive predictive value of 87% and a negative predictive value of 89% for thrombus. Duration from onset of symptoms to reoperation of <1 month separated thrombus from pannus formation. The best objective clinical parameter for prediction of thrombus was inadequate anticoagulation, whereas the best TEE parameters were qualitative and quantitative ultrasound intensity of the mass. The presence of either inadequate anticoagulation or a soft mass by TEE improved the predictive power of either parameter alone and was similar to that of ultrasound videointensity ratio. CONCLUSIONS Duration of symptoms, anticoagulation status and qualitative and quantitative ultrasound intensity of the mass obstructing a mechanical prosthetic valve can help differentiate pannus formation from thrombus and may therefore be of value in refining the selection of patients for thrombolytic therapy of prosthetic valve obstruction.
منابع مشابه
A mass obstructing mechanical prosthetic heart valve: thrombus or pannus?
Mahajan K, et al. BMJ Case Rep 2017. doi:10.1136/bcr-2017-219573 Description Mechanical prosthetic valve obstruction carries a significant morbidity and mortality, if not treated urgently. Most notable causes of an acquired obstruction include thrombosis and pannus formation. It is critically important to exclude isolated pannus, since thrombolysis is an effective and rapid treatment option in ...
متن کاملProsthetic Valve Thrombus Versus Pannus: Progress With Imaging.
P rosthetic valve obstruction is a condition associated with significant morbidity and mortality. 1 The most common causes of obstruction include valve thrombosis or pannus formation. Thrombosis is more likely to occur early after valve implantation, in the setting of inadequate anticoagulation, and is more common in mechanical prostheses. 2,3 However, it can occur with bioprostheses and may de...
متن کاملArtificial aortic valve dysfunction due to pannus and thrombus – different methods of cardiac surgical management
INTRODUCTION Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic com...
متن کاملDifferentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature.
AIMS For acquired mechanical prosthetic heart valve (PHV) obstruction and suspicion on thrombosis, recently updated European Society of Cardiology guidelines advocate the confirmation of thrombus by transthoracic echocardiography, transesophageal echocardiography (TEE), and fluoroscopy. However, no evidence-based diagnostic algorithm is available for correct thrombus detection, although this is...
متن کاملImaging of prosthetic heart valve dysfunction: complementary diagnostic value of TEE and MDCT?
P R O S T H E T I C HEART VALVES ARE INCREASINGLY IMPLANTED WORLDWIDE TO REPLACE ISEASED NATIVE V A L V E S . Prosthetic heart valve (PHV) dysfunction is rare but potentially ife-threatening. In clinical practice, transthoracic echocardiography and transesophageal echocardiogaphy, and fluoroscopy for mechanical valves, are the routine imaging modalities to evaluate suspected HV dysfunction (1)....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 32 5 شماره
صفحات -
تاریخ انتشار 1998