Effect of automation on prothrombin time test in NEQAS surveys.

نویسندگان

  • L Poller
  • J M Thomson
  • D A Taberner
چکیده

The performance of coagulometers in the National Quality Assessment Scheme (NEQAS) surveys of the prothrombin time conducted between 1986 and 1987 was reviewed. There were sufficient data for analysis for eight types of coagulometer used with a single type of thromboplastin reagent and one instrument with an alternative reagent. The overall reliability efficacy of each instrument was evaluated by determining the orthogonal regression slope parameters for prothrombin time (PT) and international normalised ratios (INR) using the manual technique as the reference method. Seven of the eight types of coagulometer tended to overestimate the INR. A pattern frequently observed with coagulometers, and difficult to regulate, was a trend to underestimate INR below 3.0 and overestimate higher INR. Overestimation of INR values over 3.0 was particularly pronounced with three types of instrument (Fibrintimer, Lancer, KC4/10). The KC4/10 was used by a sufficient number of participants to permit analysis of the performance of individual instruments. Within instrument differences were similar to those produced by different types of coagulometers. Thromboplastin reagents affected the INR values obtained with coagulometers. The study indicates that each local reagent-instrument combination must be calibrated by the participant to obtain reliable INR values. The use of a general correction factor for a local PT system seems to be invalid owing to the considerable variation in performance of individual coagulometers. The two best guides to the choice of coagulometer may be the deviation from the manual result and precision estimated by the coefficient of variation of the INR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of international sensitivity index (ISI) of thromboplastins on precision of international normalised ratios (INR)

The contribution of the thromboplastin international sensitivity index (ISI) to the interlaboratory coefficient of variation (CV) of the international normalised ratio (INR) with individual reagents was assessed. In theory the precision of the INR should increase with lower ISI values. An empirical relation has been established between the ISI, the INR, and its CV for two rabbit thromboplastins...

متن کامل

Blood Coagulation Induced by Iranian Saw-Scaled Viper (Echis Carinatus) Venom: Identification, Purification and Characterization of a Prothrombin Activator

  Objective(s): Echis carinatus is one of the venomous snakes in Iran. The venom of Iranian Echis carinatus is a rich source of protein with various factors affecting the plasma protein and blood coagulation factor. Some of these proteins exhibit types of enzymatic activities. However, other items are proteins with no enzymatic activity.   Materials and Methods: In order to study the mechanism ...

متن کامل

United Kingdom external quality assessment in blood coagulation: the first 21 years.

The external quality assessment scheme in blood coagulation has been organised from the United Kingdom Reference Laboratory for Anticoagulant Reagents and Control in Manchester since 1967. Participation has remained voluntary, but it is thought that in recent years all the hospitals performing coagulation studies have taken part. Confidentiality of the results has been maintained throughout wit...

متن کامل

Accuracy and precision of the TAS analyser for near-patient INR testing by non-pathology staff in the community.

AIMS To assess the accuracy and precision of INR measurement by trained practice and district nursing staff using the Thrombolytic Assessment System (TAS) analyser. METHODS Seventeen nurses from four practices were trained to measure INR using the TAS analyser on citrated capillary blood samples. Quality control (QC) consisted of: daily internal QC using normal and abnormal commercial plasmas...

متن کامل

Prothrombin Time, an Indicator for Psoriasis Activity: A Case - Control Study

Background: Psoriasis is a common chronic and recurrent inflammatory skin disorder related to the immune system and characterized by the rapid growth of skin cells. To date, no study has been conducted on the role of the prothrombin time index in determining the disease activity and the prognosis of these patients. Recognizing the factors influencing the prognosis of this disease can be helpf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 1989