Computational Algorithm for Estimating the Gradient Isocenter of an MRI Scanner
نویسندگان
چکیده
The isocenter of the magnetic gradient fields inside a magnetic resonance imaging scanner is an important parameter in gradient non-linearity distortion correction methods for MR images. Currently there is no established method for estimating the gradient isocenter. All existing correction methods assume that the gradient isocenter coincides with the DICOM coordinate center, which is close but not exactly the same as the gradient isocenter. A difference between gradient isocenter and DICOM coordinate center could compromise the accuracy of the correction method. The goal of this research was to develop a reasonably accurate estimation method of the 3D location of the gradient isocenter that was based on the geometry of a customdesigned phantom. We present a two-step algorithm for estimating the gradient isocenter and examine some of the possible numeric methods to be used on each step.
منابع مشابه
Estimating the Number of Wideband Radio Sources
In this paper, a new approach for estimating the number of wideband sources is proposed which is based on RSS or ISM algorithms. Numerical results show that the MDL-based and EIT-based proposed algorithm havea much better detection performance than that in EGM and AIC cases for small differences between the incident angles of sources. In addition, for similar conditions, RSS algorithm offers hi...
متن کاملPhantom Design for Distortion Correction of MR Images
AGNETIC resonance imaging (MRI) provides an excellent modality for distinguishing different tissues in the human body, which is essential for medical applications. When MRI is used for stereotactic treatment planning, its geometric accuracy is crucial. Previous studies have been conducted to correct the distortion caused by nonlinearity of the MRI scanner’s magnetic gradient fields by imaging a...
متن کاملImprovement in CT image resolution due to the use of focal spot deflection and increased sampling
When patient anatomy is positioned away from a CT scanner's isocenter, scans of limited diagnostic value may result. Yet in some cases, positioning of patient anatomy far from isocenter is unavoidable. This study examines the effect of posi-tion and reconstruction algorithm on image resolution achieved by a CT scanner operating in a high resolution (HR) scan mode which incorporates focal spot d...
متن کاملComputational Algorithm for Modeling and Correction of Gradient Nonlinearity Distortions in Magnetic Resonance Imaging
Targeting of brain tumors or diseased brain tissues with neurosurgical instruments or radiosurgery beams requires magnetic resonance image (MRI) sets with high spatial resolution. In recent years, the spatial resolution of MRI scanners has increased considerably with the introduction of highfield (3T) technology. As a result, isotropic submillimeter voxel sizes are more commonly being used for ...
متن کاملPET performance and MRI compatibility evaluation of a digital, ToF-capable PET/MRI insert equipped with clinical scintillators.
We evaluate the MR compatibility of the Hyperion-II(D) positron emission tomography (PET) insert, which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. In contrast to previous investigations, this work aims at the evaluation of a clinical crystal configuration. An imaging-capable demonstrator with an axial field-of-view of 32 mm and a crystal-to-crystal spa...
متن کامل