Monte Carlo calculated output factors of a Leksell Gamma Knife unit.

نویسندگان

  • J Y Cheung
  • K N Yu
  • R T Ho
  • C P Yu
چکیده

The Leksell Gamma Knife is a standard radiosurgical tool for treating brain lesions by directing beams of gamma radiation to a specific region. The diameter of the gamma beams is confined by collimator systems and available collimator sizes are 4, 8, 14 and 18 mm. The reduction in dose rate for each collimator helmet is called the output factor (OPF). Experimental determination of OPFs is difficult due to the extremely narrow beams for which the dose is determined. In the present work, the PRESTA version of the EGS4 Monte Carlo code was used to obtain relative OPFs for the Leksell Gamma Knife for collimator sizes of 14, 8 and 4 mm (relative to that of the 18 mm collimator). A spherical probe with a radius of 1 mm was utilized in this computer experiment. Our Monte Carlo results gave OPFs of 0.974, 0.951 and 0.872 for the 14 mm, 8 mm and 4 mm collimators respectively, relative to the 18 mm collimator. Our calculated OPF for the 4 mm collimator helmet was more than 8% higher than the value currently used, but in good agreement with the average of experimental values obtained by various Gamma Knife centres throughout the world and with the value now recommended by the manufacturer, Elekta (Elekta Instrument AB, Skeppargatan 8, S-114 52 Stockholm, Sweden).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

2 8 Ju n 20 04 1 A simplified model of the source channel of the Leksell Gamma

A simplification of the source channel geometry of the Leksell Gamma Knifer, recently proposed by the authors and checked for a single source configuration (Al-Dweri et al 2004), has been used to calculate the dose distributions along the x, y and z axes in a water phantom with a diameter of 160 mm, for different configurations of the Gamma Knife including 201, 150 and 102 unplugged sources. Th...

متن کامل

Study of scattered photons from the collimator system of Leksell Gamma Knife using the EGS4 Monte Carlo code.

In the algorithm of Leksell GAMMAPLAN (the treatment planning software of Leksell Gamma Knife), scattered photons from the collimator system are presumed to have negligible effects on the Gamma Knife dosimetry. In this study, we used the EGS4 Monte Carlo (MC) technique to study the scattered photons coming out of the single beam channel of Leksell Gamma Knife. The PRESTA (Parameter Reduced Elec...

متن کامل

Monte Carlo calculations and GafChromic film measurements for plugged collimator helmets of Leksell Gamma Knife unit.

The Monte Carlo technique and GafChromic films were employed to verify the accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (type B) radiosurgery when plugged collimator helmets were used. The EGS4 Monte Carlo code was used to calculate the dose distribution along the x, y, and z axes when a single shot was delivered at the center point (unit center point: x = 100, y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 44 12  شماره 

صفحات  -

تاریخ انتشار 1999