Robust, reliable biosensor for continuous monitoring of urea during dialysis.

نویسندگان

  • L Della Ciana
  • G Caputo
چکیده

We developed a new urea sensor for the on-line monitoring of hemodialysis adequacy. The biosensor consisted of an immobilized urease cartridge placed between magnetoinductive conductivity cells. The biosensor output was taken as the conductivity difference between these cells. The device was placed on the ultrafiltrate line of a paired filtration dialysis system. The amount of urease present in the cartridge was sufficient for the complete conversion to ammonium carbonate of urea up to 35 mmol/L. Agreement was good between the urea concentration by the biosensor method and an automated analyzer for seven patients: range 8.07-30.3 mmol/L (22.6-84.8 mg/dL blood urea nitrogen, BUN); intercept 0.20 +/- 0.1 mmol/L (0.55 +/- 0.4 mg/dL BUN); slope 1.01 +/- 0.01; r 0.997; S(y/x) 0.40 mmol/L (1.11 mg/dL BUN). The device proposed meets the requirements of accuracy, cost, ruggedness, and ease of use (no calibration required) for a biosensor to be used for continuous monitoring of hemodialysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Wavelength Selection in Ultraviolet Spectroscopy for the Estimation of Toxin Reduction Ratio during Hemodialysis

Introduction The concentration of substances, including urea, creatinine, and uric acid, can be used as an index to measure toxic uremic solutes in the blood during dialysis and interdialytic intervals. The on-line monitoring of toxin concentration allows for the clearance measurement of some low-molecular-weight solutes at any time during hemodialysis.The aim of this study was to determine the...

متن کامل

Urea rebound and delivered Kt/V determination with a continuous urea sensor.

BACKGROUND The recent introduction of urea sensors for dialysis monitoring has made possible new approaches to urea kinetic modelling. In this study we show how the equilibrated postdialysis urea concentration (Ceq) and Kt/V corrected for double-pool urea kinetics (Kt/Vdp) can be accurately determined using an on-line sensor providing a continuous measure of blood water urea. A modification of ...

متن کامل

A Novel Conductometric Urea Biosensor with Improved Analytical Characteristic Based on Recombinant Urease Adsorbed on Nanoparticle of Silicalite.

Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high re...

متن کامل

Spectrophotometric bioanalytical flow-injection system for control of hemodialysis treatment.

A spectrophotometric flow-injection analysis (FIA) system for monitoring clinical hemodialysis is demonstrated. The role of a dialysate urea detector incorporated in this bioanalytical system is played by an optical flow-through biosensor based on Prussian Blue film with chemically linked urease forming a monomolecular layer of the enzyme. This pH-enzyme optode-FIA system is useful for the sele...

متن کامل

Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance.

BACKGROUND An on-line monitoring system for dialysis dose calculations could make it possible to provide an adequate dialysis dose that is consistently given to haemodialysis (HD) patients. The aim of this study was to compare dialysis dose (Kt/V) using four different methods and their sensitiveness to a reduction in clearance. METHODS Six patients were monitored on-line with ultraviolet (UV)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 7  شماره 

صفحات  -

تاریخ انتشار 1996